Related Experiment Video
Updated: Jun 17, 2026

Sterile Pericarditis in Aachener Minipigs As a Model for Atrial Myopathy and Atrial Fibrillation
Published on: September 24, 2021
High-density biatrial pacing protects against atrial fibrillation by synchronizing left atrial tissue
James C Hansen1, Rakesh Latchamsetty, Nimrod Lavi
1University of Illinois at Chicago Section of Cardiology, Chicago, IL 60612, USA.
Purpose:
The induction and sustainability of atrial fibrillation (AF) are most commonly due to pulmonary vein (PV) triggers and left atrial (LA) substrate. We hypothesized that simultaneous pacing of the PV ostia, LA, and right atrium (RA) reduces AF susceptibility by synchronizing atrial activity.
Methods:
Mongrel dogs were rapidly paced and maintained in AF for 3 months before cardioversion. Pacing leads were then placed at PV ostia, LA, and RA sites. For single-site pacing (SSP), a drive train (S1) and premature stimulus (S2) were delivered from the same electrode. Multisite pacing (MSP) consisted of S1 at all leads simultaneously and S2 at one site. Pacing trials were performed with decremental S2 coupling intervals (CI) to endpoints of AF induction or refractoriness.
Results:
AF induction was reduced by 40.0% with MSP vs. SSP (7.2% vs. 12.0%, p < 0.001). LA S2 sites were more likely to induce AF than RA sites (11.5% vs. 2.6%, p < 0.0001), with benefit of MSP over SSP at LA sites (8.6% vs. 14.6%, p < 0.0001). The CI for AF induction was longer with SSP vs. MSP (119.4 +/- 13.3 vs. 104.4 +/- 11.2 ms, p < 0.05). Atrial activation times were shortened with MSP vs. SSP (87.4 +/- 4.9 vs. 97.1 +/- 10 ms, p < 0.005).
Conclusions:
Atrial synchronization was shown by the decreased activation times with MSP. AF induction was reduced by 40.0% with MSP, supporting the hypothesis of decreased AF susceptibility with synchronization. This is the first study demonstrating AF protection with high-density pacing at LA sites associated with triggers and substrate for the induction and maintenance of AF.
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias VI: Management of Dysrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Mechanism of Cardiac Arrhythmias
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...