Related Experiment Video
Updated: Jun 17, 2026

Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
Highly selective GC stationary phases consisting of binary mixtures of polymeric ionic liquids
Qichao Zhao1, Jared L Anderson
1Department of Chemistry, The University of Toledo, Toledo, OH 43615, USA.
Abstract:
GC stationary phases composed of binary mixtures of two polymeric ionic liquids (PILs), namely, poly(1-vinyl-3-hexylimidazolium) bis[(trifluoromethyl)sulfonyl]imide (poly(ViHIm-NTf(2)))/poly(1-vinyl-3-hexylimidazolium) chloride (poly(ViHIm-Cl)) and poly(1-vinyl-3-hexadecylimidazolium) bis[(trifluoromethyl)sulfonyl]imide (poly(ViHDIm-NTf(2)))/poly(1-vinyl-3-hexadecylimidazolium) chloride (poly(ViHDIm-Cl)), were evaluated in terms of their on-set bleed temperature and separation selectivity. A total of six neat or binary PIL stationary phases were characterized using the solvation parameter model to investigate the effects of the polymeric cation and anion and PIL composition on the system constants of the resulting stationary phases. The hydrogen bond basicity of the mixed poly(ViHIm-NTf(2))/poly(ViHIm-Cl) stationary phases was enriched linearly with the increase in the poly(ViHIm-Cl) content. Results revealed that tuning the composition of the stationary phase allowed for fine control of the retention factors and separation selectivity for alcohols and carboxylic acids as well as selected ketones, aldehydes, and aromatic compounds. A reversal of elution order was observed for particular classes of analytes when the weight percentage of the chloride-based PIL was increased.
More Related Videos
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
06:44From Molecules to Materials: Engineering New Ionic Liquid Crystals Through Halogen Bonding
Published on: March 24, 2018
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
High-Performance Liquid Chromatography: Elution Process