Observation of plastoquinone kinetics in photosystem II from delayed fluorescence measurements

Y Guo1, B Wirth, J Tan

  • 1University of Missouri, Department of Biological Engineering, Columbia, MO 65211, USA.

IET Systems Biology
|December 17, 2009
PubMed

Related Concept Videos

Photosystem II01:22

Photosystem II

The multi-protein complex photosystem II (PS II) harvests photons and transfers their energy through its bound pigments to its reaction center, and ultimately to photosystem I (PSI) through the electron transport chain. The pigments responsible for caputirng the light energy in photosystems include chlorophyll a, chlorophyll b, and carotenoids.
The pigment molecules are arranged across  two photosystem domains — the antenna complex and the reaction center. The main aim of the pigment molecules...
Photosystem I01:27

Photosystem I

Although structurally similar to photosystem II (PSII), photosystem I (PSI) is has a different electron supplier and electron acceptor.
Both these photosystems work in concert. An excited electron from PSII is relayed to PSI via an electron transport chain in the thylakoid membrane of the chloroplast, which is comprised of the carrier molecule plastoquinone, the dual-protein cytochrome complex, and plastocyanin. As electrons move between PSII and PSI, they lose energy and must be re-energized...
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
Protein Dynamics in Living Cells01:19

Protein Dynamics in Living Cells

Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
The Photochemical Reaction Center01:29

The Photochemical Reaction Center

Reaction centers are pigment-protein complexes that initiate energy conversion from photons to chemical entities. Therefore, photochemical reaction center is a more appropriate term that describes these complexes. The Nobel laureates Robert Emerson and William Arnold provided the first experimental evidence of photochemical reaction centers by demonstrating the participation of nearly 2,500 chlorophyll molecules for the release of just one molecule of oxygen. Despite thousands of photosynthetic...