Related Experiment Video
Updated: Jun 17, 2026

Generation of Two-color Antigen Microarrays for the Simultaneous Detection of IgG and IgM Autoantibodies
Published on: September 15, 2016
A dual antiglobulin test for the detection of weak or nonagglutinating immunoglobulin M warm autoantibodies
Thilo Bartolmäs1, Abdulgabar Salama
1Institute for Transfusion Medicine, Charité-University Medicine, Berlin, Germany.
Background:
Immunoglobulin (Ig)M warm autoantibodies (AABs) usually cause severe autoimmune hemolytic anemia (AIHA) and, in some cases, red blood cell (RBC)-bound IgM cannot be detected. We describe a simple dual antiglobulin test (DDAT) for diagnosing such cases.
Study Design And Methods:
A patient with erroneously suspected cold agglutinin syndrome was investigated. The direct antiglobulin test (DAT) was performed using standard techniques and dual (two stages) antiglobulin reagents (IgG rabbit anti-human IgM, IgG goat anti-rabbit IgG).
Results:
A cold agglutinin syndrome was diagnosed initially, as the patient's serum was reactive with RBCs at a temperature of 28 degrees C or less, and the DAT was strongly positive with anti-C(3)d. Six months later, the patient was reexamined at this hospital due to progressive hemolysis. His RBCs were found to be coated with IgM warm AABs that only became detectable using a DDAT, and his serum contained only a weak cold agglutinin. The hemolysis remained refractory to treatment with prednisolone and also prednisolone plus azathioprine, but gradually improved after treatment with prednisolone plus cyclophosphamide.
Conclusion:
Weak or nonagglutinating RBC-bound IgM warm antibodies can be identified by the presented DDAT.
More Related Videos
Related Concept Videos
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Blood Typing
Antigens are protein molecules that reside on the surface of red blood cells (RBCs). The ABO and Rh blood typing systems target antigens A,...
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.