Terahertz absorption spectra of original and generic ceftazidime

Masaya Kawase1, Tadashi Saito, Masafumi Ogawa

  • 1Nagahama Institute of Bio-science and Technology, 1266 Tamura, Nagahama, Shiga 526-0829, Japan. m_kawase@nagahama-i-bio.ac.jp

Related Concept Videos

Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence01:22

Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence

Generic intravenous (IV) drugs are considered bioequivalent to their branded counterparts due to their 100% bioavailability upon administration. However, variations in stability among different drug products can significantly influence their therapeutic performance, even if they are pharmaceutically equivalent.Cefuroxime, a prophylactic antimicrobial, is often used as a single-dose IV injection for patients undergoing coronary artery bypass grafting surgery. A 3 g dose typically provides...
IR Frequency Region: Fingerprint Region01:03

IR Frequency Region: Fingerprint Region

IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the C=O, C=N, and C=C occur between 1600–1850 cm−1.
The...
IR Spectrum01:19

IR Spectrum

When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Spectroscopy of Carboxylic Acid Derivatives01:26

Spectroscopy of Carboxylic Acid Derivatives

Infrared spectroscopy is primarily used to determine the types of bonds and functional groups. In carboxylic acid derivatives, a typical carbonyl bond absorption is observed around 1650–1850 cm−1. For esters, the absorption is recorded at around 1740 cm−1, while acid halides show the absorption at about 1800 cm−1. Another acid derivative, the acid anhydrides, exhibit two carbonyl absorption around 1760 cm−1 and 1820 cm−1, arising from the symmetrical and unsymmetrical carbonyl vibration.
In the...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...