Related Experiment Video
Updated: Jun 17, 2026

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse
Published on: October 24, 2018
A new miniaturized system for extracorporeal membrane oxygenation in adult respiratory failure
Thomas Müller1, Alois Philipp, Andreas Luchner
1Department of Medicine II, University Hospital Regensburg, 93053 Regensburg, Germany. thomas.mueller@klinik.uni-regensburg.de
Introduction:
Mortality of severe acute respiratory distress syndrome in adults is still unacceptably high. Extracorporeal membrane oxygenation (ECMO) could represent an important treatment option, if complications were reduced by new technical developments.
Methods:
Efficiency, side effects and outcome of treatment with a new miniaturized device for veno-venous extracorporeal gas transfer were analysed in 60 consecutive patients with life-threatening respiratory failure.
Results:
A rapid increase of partial pressure of arterial oxygen/fraction of inspired oxygen (PaO2/FiO2) from 64 (48 to 86) mmHg to 120 (84 to 171) mmHg and a decrease of PaCO2 from 63 (50 to 80) mmHg to 33 (29 to 39) mmHg were observed after start of the extracorporeal support (P < 0.001). Gas exchange capacity of the device averaged 155 (116 to 182) mL/min for oxygen and 210 (164 to 251) mL/min for carbon dioxide. Ventilatory parameters were reduced to a highly protective mode, allowing a fast reduction of tidal volume from 495 (401 to 570) mL to 336 (292 to 404) mL (P < 0.001) and of peak inspiratory pressure from 36 (32 to 40) cmH2O to 31 (28 to 35) cmH2O (P < 0.001). Transfusion requirements averaged 0.8 (0.4 to 1.8) units of red blood cells per day. Sixty-two percent of patients were weaned from the extracorporeal system, and 45% survived to discharge.
Conclusions:
Veno-venous extracorporeal membrane oxygenation with a new miniaturized device supports gas transfer effectively, allows for highly protective ventilation and is very reliable. Modern ECMO technology extends treatment opportunities in severe lung failure.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-IV
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...