Related Experiment Videos
Comparative performance of short-term diffusion barrier charcoal canisters and long-term alpha-track monitors for
D E Martz1, J L George, G H Langner
1Chem-Nuclear Geotech, Inc., U.S. Department of Energy, Grand Junction, CO 81502.
Abstract:
The accuracy and precision of indoor 222Rn measurements obtained with the use of diffusion barrier charcoal canisters (DBCC) under actual field conditions were determined by comparing the integrated average of 26 successive 7-d exposures of DBCC in each of 16 occupied residences over a 6-mo period with simultaneous measurements using four types of commercially available alpha-track monitors (ATM) and one type of scintillation chamber continuous 222Rn monitor. The results suggest that properly calibrated DBCCs provide very good estimates of the integrated 222Rn concentrations in residential structures over the standard 1-wk exposure period despite the occurrence of large diurnal variations in the actual 222Rn concentrations. The results also suggest that a relatively small number of 1-wk DBCC measurements at selected times throughout the calendar year would provide estimates of the annual average indoor 222Rn concentrations that compare favorably with single long-term ATM measurements.