Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
A method for the analysis of tabun in multisol using gas chromatographic flame photometric detection
Thomas P Logan1, Edward D Allen, Mark R Way
1Drug Assessment Division and Pharmacology Division, United States Army Medical Research Institute of Chemical Defense, Aberdeen Proving Ground, Maryland, USA.
Abstract:
Preparation and analysis of tabun (GA) solutions are necessary for the continued development of countermeasures to this nerve agent. GA solutions must be stable and compatible for use in the test systems chosen for study; however, GA is very unstable in saline solutions. In the past we have found GA in saline at 2 mg/mL to be stable for a month or less at -70 degrees C, whereas saline solutions of sarin (GB), soman (GD), and cyclosarin (GF) were stable for many months. Previous studies have shown that Multisol (48.5% H(2)O, 40% propylene glycol, 10% ethanol, and 1.5% benzyl alcohol) provides stable solutions of GA. We confirmed the stability of GA in Multisol with phosphorus nuclear magnetic resonance (P horizontal line NMR) and developed a method for the analysis of GA in Multisol using gas chromatographic flame photometric detection (GCFPD) in the phosphorus mode. The GC method used acetonitrile (CH(3)CN) for a dilution solvent because of its miscibility with GA in chloroform (CHCl(3)) standards and GA in Multisol samples at 1% (v/v). Furthermore, the dilutions with CH(3)CN made the phosphorus mode interference peak present in CHCl(3) analytically manageable, reduced the interferences of Multisol in the GC separation, and contributed to a safe and reliable analysis of GA at 20 mug/mL. We demonstrated the stability of GA in Multisol stored for more than a year at 70 degrees C. This method contributes a suitable technique for the preparation and analysis of reliable solutions of GA in nerve agent medical research and demonstrates the extended stability of GA in Multisol.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Flame Photometry: Overview
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Flame Photometry: Lab
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...