Three-Dimensional Modeling of the Left Atrium and Pulmonary Veins with a Precise Intracardiac Echocardiography Approach
Published on: June 30, 2023
Three-dimensional CT overlay in comparison to CartoMerge for pulmonary vein antrum isolation
Jeroen Stevenhagen1, Pepijn H Van Der Voort, Lukas R C Dekker
1Department of Cardiology, Catharina Hospital, Eindhoven, the Netherlands.
Introduction:
Three-dimensional (3D) navigation systems are widely used for pulmonary vein antrum isolation (PVAI). To circumvent left atrial (LA) mapping, 3D CT reconstructions of the LA can be superimposed directly (CT overlay) on the fluoroscopy image to guide ablation catheters and to mark ablation sites.
Methods And Results:
Sixty-eight patients (pts) with symptomatic AF refractory to medical therapy were randomly assigned to CT overlay (group 1, n = 38) or CartoMerge (group 2, n = 30). In group 1 registration of the CT image was performed with contrast injections in 2 orthogonal projections. In group 2, visualization of all pulmonary vein (PV) ostia was done by PV angiography, followed by merging of the CT image and the Carto shell. We compared procedural success, procedure time, fluoroscopy time and radiation burden, measured as dose area product (DAP). Baseline characteristics were comparable in both groups. Procedural success, defined as disappearance of PV potentials in all PVs, was achieved in 37/38 (97%) of group 1 patients and 27/30 (90%) patients in group 2 (P = NS). Total procedure time was significantly shorter in group 1 compared to group 2 (129 +/- 34 vs 181 +/- 30 min, P < 0.0001). Although fluoroscopy time tended to be longer in the CT overlay group (47 +/- 16 vs 40 +/- 13 min, P = 0.06), proper use of diaphragmation resulted in comparable radiation values for both groups (DAP 53 +/- 27 vs 56 +/- 35 Gy cm(2), P = 0.76).
Conclusions:
CT overlay for PV isolation is feasible and may, in comparison to conventional LA navigation systems, shorten procedural time without increases in radiation burden.
More Related Videos
06:48Three-Dimensional Echocardiographic Method for the Visualization and Assessment of Specific Parameters of the Pulmonary Veins
Published on: October 28, 2020
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography