Related Experiment Video
Updated: Jun 17, 2026

Simple Continuous Glucose Monitoring in Freely Moving Mice
Published on: February 24, 2023
Time lag characterization of two continuous glucose monitoring systems
Satish K Garg1, Mary Voelmle, Peter A Gottlieb
1Barbara Davis Center for Childhood Diabetes, University of Colorado Denver, School of Medicine, Aurora, CO 80045, United States. satish.garg@ucdenver.edu
Aim:
To evaluate the system time lag associated with subcutaneous interstitial glucose (IG) sensing and venous blood glucose (BG) of two continuous glucose monitoring (CGM) systems, the SEVEN((R)) (DexCom, San Diego, CA) and the Navigator((R)) (Abbott Diabetes Care, Alameda, CA), in adults with type 1 diabetes.
Methods:
Fourteen subjects wore both CGM systems concurrently during the 15-day study. Reference YSI (Yellow Springs, OH) and CGM data from the in-clinic sessions, conducted on day 5, 10 and 15 of the study were evaluated. The system time lag of CGM system was estimated using various regression method related statistical estimators.
Results:
The estimated time lags based on different statistical measures are similar within each CGM system. The time lag based on correlation coefficient criteria is estimated as 4.5+/-5min (median+/-IQR) for the SEVEN((R)), and 15+/-7min for the Navigator((R)). The ranges of these estimators of two CGM systems were different (2-6min for SEVEN((R)) and 14-15min for Navigator((R))).
Conclusions:
The study findings suggest that commonly accessible statistics, such as correlation statistics, offer estimates that are comparable to complicated approaches. Different time lags were observed with two CGM systems.
Related Concept Videos
Oral Drug Delivery Systems: Continuous-Release Systems
Classification of Systems-II
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the lowest drug...
Pharmacodynamic Models: Link Model and Systems Pharmacodynamic Model