Related Experiment Video
Updated: Jun 17, 2026

Measurement of Liver Stiffness Using Atomic Force Microscopy Coupled with Polarization Microscopy
Published on: July 20, 2022
Liver stiffness is directly influenced by central venous pressure
Gunda Millonig1, Stefanie Friedrich, Stefanie Adolf
1Department of Medicine and Center for Alcohol Research, Liver Disease and Nutrition, Salem Medical Center, University of Heidelberg, Heidelberg, Germany.
Background & Aims:
Liver stiffness (LS) as measured by transient elastography [Fibroscan] offers a novel non-invasive approach to assess liver cirrhosis. Since Fibroscan seems to be unreliable in patients with congestive heart failure, it remains to be determined whether hemodynamic changes affect LS irrespective of fibrosis.
Methods & Results:
Using landrace pigs, we studied the direct relationship between the central venous pressure and LS measured by Fibroscan. Clamping of the inferior caval vein increased LS from 3.1 to 27.8kPa while reopening reversed LS within 5min to almost normal values of 5.1kPa. We then studied LS as a function of venous pressure in the isolated pig liver by clamping the upper and lower caval, portal vein and hepatic artery. The stepwise increase of intravenous pressure to 36cm of water column (3.5kPa) linearly and reversibly increased LS to the upper detection limit of 75kPa. We finally measured LS in 10 patients with decompensated congestive heart failure before and after recompensation. Initial LS was elevated in all patients, in 8 of them to a degree that suggested liver cirrhosis (median 40.7kPa). Upon recompensation with a median weight loss of 3.0kg, LS decreased in all 10 patients down to a median LS of 17.8kPa. Inflammation could not account for increased LS since initial liver enzyme counts were only slightly elevated and did not change significantly.
Conclusion:
LS is a direct function of central venous pressure which should be considered when assessing the degree of fibrosis.
Related Concept Videos
Portal Hypertension
Cirrhosis II: Pathophysiology
Effect of Hepatic Disease on Pharmacokinetics: Drug Dosing and Hepatic Blood Flow
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol abuse, or...
Veins as Blood Reservoirs