Related Experiment Video
Updated: Jun 17, 2026

Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Published on: December 12, 2025
Building characterization and aerosol infiltration into a naturally ventilated three-story apartment building
Charles E Rodes1, Douglas W Vanosdell, Jeffrey W Portzer
1RTI International, 3040 Cornwallis Road, P.O. Box 12194, Research Triangle Park, NC 27709, USA. charlesr@rti.org
Abstract:
Understanding infiltration of outdoor pollutants was an integral part of the Brooklyn Traffic Real-Time Ambient Pollutant Penetration and Environmental Dispersion (B-TRAPPED) study. For this reason, the structural and air exchange properties of the three-story row house in Brooklyn, NY, USA, that was used in the B-TRAPPED experiments were fully characterized. Factors investigated included representativeness of the construction and impact of building design features on the natural ventilation and infiltration of outdoor aerosol. Both blower door and perfluorocarbon tracer (PFT) air exchange rate (AER) experiments showed that the ventilation rates of the building were quite typical of similar structures in the New York City (NYC) metropolitan area. Indoor/outdoor (I/O) aerosol count ratios by particle size were comparable to a similar vintage naturally ventilated building in Boston, MA, USA. I/O ratio analyses were consistent with literature findings and showed I/O ratios ranging from 0.310 to 0.601, varying across particle sizes (from 0.3 to 5.0 [corrected] mum) and between first and second floor apartments. An effort to apply the rebound method of Thatcher et al. (Aerosol Sci. Technol., 2003, 37, 847-864) in determining aerosol infiltration rates proved unsuccessful due to unexpectedly long (>60 min) equilibration times after the filtration period. Uninsulated interior wall renovations in the study house created a cavity that resulted in a large intermediate dead volume (for infiltration) that apparently could not be accommodated by a simple infiltration model. Simple two-compartment models evidently have finite application limitations for even modestly complex settings.
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh.
Masonry Cavity Walls
Maintaining a clean cavity during construction is...
Masonry Curtain Walls
Cavity Drainage and Flashings in Masonry walls
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Composite Masonry Walls
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200 feet...