Comparing methods of measuring treatment intensification in hypertension care
Adam J Rose1, Dan R Berlowitz, Meredith Manze
1Center for Health Quality, Outcomes, and Economic Research, Bedford VA Medical Center, Bedford, MA 01730, USA. adamrose@bu.edu
Background:
Greater treatment intensification (TI) improves hypertension control. However, we do not know the ideal way to measure TI for research and quality improvement efforts. We compared the ability of different TI measures to predict blood pressure (BP) control.
Methods And Results:
We enrolled 819 hypertensive outpatients from an urban academic hospital. Each patient was assigned 3 scores to characterize TI. The any/none score divides patients into those who had any therapy increases during the study versus none. The norm-based method models the chance of a medication increase at each visit, then scores each patient based on whether they received more or fewer medication increases than predicted. The standard-based method is similar to the norm-based method but expects a medication increase whenever the blood pressure is uncontrolled. We compared the ability of these scores to predict the final systolic blood pressure (SBP). The any/none score showed a paradoxical result: any therapy increase was associated with SBP 4.6 mm Hg higher than no increase (P<0.001). The norm-based method score did not predict SBP in a linear fashion (P=0.18); further investigation revealed a U-shaped relationship between the norm-based method score and SBP. However, the standard-based method score was a strong linear predictor of SBP (2.1 mm Hg lower for each additional therapy increase per 10 visits, P<0.001). Similarly, the standard-based method predicted dichotomized blood pressure control, as measured by SBP <140 mm Hg (odds ratio, 1.30; P<0.001).
Conclusions:
Our results suggest that standard-based method is the preferred measure of treatment intensity for hypertension care.
Related Concept Videos
Hypertension IV: Drug Therapy and Lifestyle Modifications
Hypertension III: Clinical Manifestations and Diagnostic Studies
Hypertension V: Nursing Management
Heart Failure V: Medical Management
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.