Related Experiment Video
Updated: Jun 17, 2026

A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
Published on: May 19, 2023
[Evaluation of a computer aided detection system for lung nodules with ground glass opacity component on
C Beigelman-Aubry1, C Hill, X Boulanger
1Service de Radiologie, Hôpital Pitié-Salpêtrière, AP-HP, Université Pierre et Marie Curie, 47-83, boulevard de l'Hôpital, 75651 Paris cedex 13.
Purpose:
To determine the performance of a CAD system for lung nodules with ground glass opacity component on multidetector-row CT. Materials and methods. The CT examinations of 17 patients with at least one persistent subsolid nodule were reviewed. A first non-blinded consensus review by two expert radiologists resulted in the detection of 104 subsolid nodules larger than 3 mm (74 nodules of ground glass attenuation and 30 mixed nodules with solid and ground glass components). The results from this review were used as a gold standard to determine the performances of the CAD system and 3 independent clinical radiologists involved with the primary interpretations.
Results:
The sensitivity of the CAD system for the detection of ground glass opacities and mixed nodules was 53% and 73% respectively. These values were not statistically different from the values for the 3 independent observers (42-66% for ground glass opacities and 63-80% for mixed nodules). The sensitivity of each observer significantly increased when the nodules detected by the CAD system were added to those detected by each observer (p<0.0001).
Conclusion:
A CAD system has a potential impact on the detection rate of subsolid nodules by radiologists.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography