Background:
To optimally exploit the potential added diagnostic and prognostic value of new left ventricular (LV) deformation parameters, better understanding of LV mechanics in aortic stenosis (AS) is warranted. We sought to determine a broad spectrum of LV rotation parameters in AS patients and age-matched healthy controls, in order to gain insight into the mechanical properties of the LV in AS.
Methods:
The study comprised 48 AS patients with an aortic valve area<2.0 cm2 and LV ejection fraction>50%, and 24 healthy--for age and gender matched--control subjects. LV peak systolic rotation (Rotmax), LV peak systolic twist (Twistmax), untwisting rate (mean diastolic untwisting velocity from Twistmax to mitral valve opening), peak diastolic untwisting velocity, and time-to-peak diastolic untwisting velocity were determined by speckle tracking echocardiography.
Results:
AS patients had normal basal Rotmax and increased apical Rotmax, resulting in increased Twistmax (13.4±4.0° vs. 11.4±2.7°, P<0.05). Apical Rotmax and Twistmax correlated significantly to echo-Doppler indicators of AS severity. Time-to-peak diastolic untwisting velocity was increased (20±10% vs. 15±9%, P<0.05) and untwisting rate was decreased (-38±21°/s vs. -50±28°/s, P<0.01) in AS patients.
Conclusions:
Twistmax increases proportionally to the severity of AS, which might serve as a compensatory mechanism to maintain systolic LV function. LV diastolic untwisting is delayed and the untwisting rate is reduced in AS.
More Related Videos
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Related Concept Videos
Mitral Stenosis I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
Mitral Stenosis II: Clinical features and Diagnostic Tests
Thoracic Aorta
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...