[Diffusion-weighted MR imaging for postoperative nodal recurrence of esophageal squamous cell cancer in comparison

Kiyohiko Shuto1, Hiroshige Saito, Gaku Ohira

  • 1Department of Frontier Surgery, Graduate School of Medicine, Chiba University.

Insights

Diffusion-weighted whole-body imaging with background suppression (DWIBS) effectively detects esophageal cancer recurrence in lymph nodes, showing performance comparable to FDG-PET scans. This noninvasive technique offers a reliable alternative for diagnosing nodal recurrence.

Area of Science:

  • Oncology
  • Radiology
  • Medical Imaging

Background:

  • Esophageal cancer recurrence, particularly in lymph nodes, poses a significant clinical challenge.
  • Accurate detection of nodal recurrence is crucial for effective patient management and treatment planning.
  • Fluorodeoxyglucose-positron emission tomography (FDG-PET) is a standard imaging modality for recurrence detection.

Purpose of the Study:

  • To evaluate the diagnostic power of Diffusion-Weighted Whole-Body Imaging with Background Suppression (DWIBS) for detecting postoperative lymph node recurrence of esophageal cancer.
  • To compare the efficacy of DWIBS with Fluorodeoxyglucose-Positron Emission Tomography (FDG-PET) in identifying recurrent esophageal cancer.
  • To assess the diagnostic accuracy of apparent diffusion coefficient (ADC) values in differentiating recurrent lymph nodes from normal esophageal tissue.

Main Methods:

  • A study involving 47 patients with suspected lymph node recurrence of esophageal cancer, identified by multi-detector computed tomography (MDCT).
  • Comparison of diagnostic performance metrics (sensitivity, positive predictive value, overall accuracy) between DWIBS and FDG-PET.
  • Measurement and analysis of apparent diffusion coefficient (ADC) values for recurrent nodes, primary cancer, and normal esophagus.

Main Results:

  • DWIBS demonstrated high sensitivity (95%) and positive predictive value (83%), comparable to FDG-PET (97% sensitivity, 90% PPV).
  • Overall accuracy rates for DWIBS (81%) and FDG-PET (87%) were not significantly different.
  • Recurrent lymph nodes exhibited significantly lower ADC values (1.124 x10(-3) mm2/s) compared to normal esophagus (2.079 x10(-3) mm2/s) (p<0.0001).
  • A cut-off ADC value of 1.5 x10(-3) mm2/s achieved 100% accuracy in distinguishing recurrent lesions from normal esophageal tissue.

Conclusions:

  • Noninvasive DWIBS is a valuable imaging modality for discriminating nodal recurrence in esophageal cancer patients.
  • DWIBS exhibits diagnostic performance comparable to FDG-PET for detecting lymph node recurrence.
  • ADC measurements using DWIBS provide a reliable method for differentiating recurrent esophageal cancer from normal tissue.

Related Concept Videos

Radiological Investigation III: Pulmonary Angiogram and PET Scan01:13

Radiological Investigation III: Pulmonary Angiogram and PET Scan

Radiological investigations are paramount in the diagnosis and management of various pulmonary diseases. Two essential investigations are the Pulmonary Angiogram and the Positron Emission Tomography (PET) Scan.
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...