Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
[Diffusion-weighted MR imaging for postoperative nodal recurrence of esophageal squamous cell cancer in comparison
Kiyohiko Shuto1, Hiroshige Saito, Gaku Ohira
1Department of Frontier Surgery, Graduate School of Medicine, Chiba University.
Abstract:
We evaluated the power of DWIBS in patients with postoperative lymph node recurrence of esophageal cancer and compared with FDG-PET findings. Forty-seven suspected lesions by MDCT were enrolled. No significant difference between DWIBS and PET was observed in sensitivity (95% vs 97%), PPV (83% vs 90%) and overall accuracy rate (81% vs 87%). The ADCs (x10(-3) mm2/s) of recurrent nodes, primary cancer and normal esophagus were 1.124, 1.058 and 2.079, respectively. ADCs of recurrent nodes were significantly lower than those of normal esophagus (p<0.0001). The cut-off ADC line of 1.5 revealed 100% overall accuracy for separating the recurrent lesion from normal esophagus. Noninvasive DWIBS may become a valid modality to discriminate nodal recurrence of esophageal cancer by no means inferior to PET.
Insights
Diffusion-weighted whole-body imaging with background suppression (DWIBS) effectively detects esophageal cancer recurrence in lymph nodes, showing performance comparable to FDG-PET scans. This noninvasive technique offers a reliable alternative for diagnosing nodal recurrence.
Area of Science:
- Oncology
- Radiology
- Medical Imaging
Background:
- Esophageal cancer recurrence, particularly in lymph nodes, poses a significant clinical challenge.
- Accurate detection of nodal recurrence is crucial for effective patient management and treatment planning.
- Fluorodeoxyglucose-positron emission tomography (FDG-PET) is a standard imaging modality for recurrence detection.
Purpose of the Study:
- To evaluate the diagnostic power of Diffusion-Weighted Whole-Body Imaging with Background Suppression (DWIBS) for detecting postoperative lymph node recurrence of esophageal cancer.
- To compare the efficacy of DWIBS with Fluorodeoxyglucose-Positron Emission Tomography (FDG-PET) in identifying recurrent esophageal cancer.
- To assess the diagnostic accuracy of apparent diffusion coefficient (ADC) values in differentiating recurrent lymph nodes from normal esophageal tissue.
Main Methods:
- A study involving 47 patients with suspected lymph node recurrence of esophageal cancer, identified by multi-detector computed tomography (MDCT).
- Comparison of diagnostic performance metrics (sensitivity, positive predictive value, overall accuracy) between DWIBS and FDG-PET.
- Measurement and analysis of apparent diffusion coefficient (ADC) values for recurrent nodes, primary cancer, and normal esophagus.
Main Results:
- DWIBS demonstrated high sensitivity (95%) and positive predictive value (83%), comparable to FDG-PET (97% sensitivity, 90% PPV).
- Overall accuracy rates for DWIBS (81%) and FDG-PET (87%) were not significantly different.
- Recurrent lymph nodes exhibited significantly lower ADC values (1.124 x10(-3) mm2/s) compared to normal esophagus (2.079 x10(-3) mm2/s) (p<0.0001).
- A cut-off ADC value of 1.5 x10(-3) mm2/s achieved 100% accuracy in distinguishing recurrent lesions from normal esophageal tissue.
Conclusions:
- Noninvasive DWIBS is a valuable imaging modality for discriminating nodal recurrence in esophageal cancer patients.
- DWIBS exhibits diagnostic performance comparable to FDG-PET for detecting lymph node recurrence.
- ADC measurements using DWIBS provide a reliable method for differentiating recurrent esophageal cancer from normal tissue.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...