Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration01:16

IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration

A covalently bonded heteronuclear diatomic molecule can be modeled as two vibrating masses connected by a spring. The vibrational frequency of the bond can be expressed using an equation derived from Hooke's law, which describes how the force applied to stretch or compress a spring is proportional to the displacement of the spring. In this case, the atoms behave like masses, and the bond acts like a spring.
According to Hooke's law, the vibrational frequency is directly proportional to the...
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
UV–Vis Spectroscopy: Woodward–Fieser Rules01:29

UV–Vis Spectroscopy: Woodward–Fieser Rules

UV–Visible absorption spectra of conjugated dienes arise from the lowest energy π → π* transitions. The light-absorbing part of the molecule is called the chromophore, and the substituents directly attached to the chromophore are called auxochromes. A strong correlation exists between the absorption maxima, λmax, and the structure of a conjugated π system. The Woodward–Fieser rules predict the value of λmax for a given structure by adding the contributions...
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
IR Spectroscopy: Molecular Vibration Overview01:24

IR Spectroscopy: Molecular Vibration Overview

When Infrared (IR) radiation passes through a covalently bonded molecule, the bonds transition from lower to higher vibrational levels. The fundamental vibrational motions that result in infrared absorption can be classified as stretching or bending vibrations.
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Structurally Defined Low-Coordination Single-Atom Strategy for CO<sub>2</sub> Photoconversion to Formic Acid.

Journal of the American Chemical Society·2026
Same author

DKK3-CKAP4 signaling drives fibroimmune remodeling and hair follicle miniaturization in androgenetic alopecia.

Theranostics·2026
Same author

Personal PM<sub>2.5</sub>-Bound Metal Exposure Profiles and Their Associations with Inflammatory Biomarkers among Older Adults in Beijing.

Environmental science & technology·2026
Same author

Pharmacophore-Based QSAR Model of Multi Scaffolds as NAMPT Inhibitors & Scaffold Diversity Analysis.

Molecules (Basel, Switzerland)·2026
Same author

Venlafaxine reverses chemotherapy-induced alopecia through epithelial and dermal reprogramming at single-cell resolution.

Biomedicine & pharmacotherapy = Biomedecine & pharmacotherapie·2026
Same author

Insights into the context-dependent immunological roles of the CXCL12-CXCR4 axis in alopecia.

Frontiers in immunology·2026
Same journal

The Laser Rangefinder System in Quadrature Modem and Ambiguity Resolution.

Guang pu xue yu guang pu fen xi = Guang pu·2018
Same journal

Improving the Accuracy of Camera-Based Heart Rate Measurement.

Guang pu xue yu guang pu fen xi = Guang pu·2018
Same journal

Determination of Pb, Cr, Cd, and As in Aluminum-Plastic Packaging Materials via Inductively Coupled Plasma-Mass Spectrometry with Microwave Digestion.

Guang pu xue yu guang pu fen xi = Guang pu·2018
Same journal

Study on Molecular Recognition of Cucurbit[6]uril with Oxytetracycline Molecules by Spectroscopic Methods.

Guang pu xue yu guang pu fen xi = Guang pu·2018
Same journal

Preparation and Properties of Novel Polymer Blue Fluorescent Materials.

Guang pu xue yu guang pu fen xi = Guang pu·2018
Same journal

Effect of the Nitrogen Incorporation on the Microstructure and Photoelectric Properties of N Type Nanocrystalline Silicon Thin Films.

Guang pu xue yu guang pu fen xi = Guang pu·2018
See all related articles

Related Experiment Video

Updated: Jun 17, 2026

ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis
07:11

ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis

Published on: August 19, 2021

Automatically smoothing the spectroscopic data by Cubic B-spline basis functions.

Meng-Hua Zhu1, Liang-Gang Liu, Mei Zheng

  • 1Space Exploration Laboratory, Macao University of Science and Technology, Macao, China. peter_zu@163.com

Guang Pu Xue Yu Guang Pu Fen Xi = Guang Pu
|December 30, 2009
PubMed
Summary
This summary is machine-generated.

A new criterion using Cubic B-spline functions optimizes curve fitting for spectroscopic data noise reduction. This method automatically determines smoothing conditions, outperforming traditional residual sum of squares approaches.

More Related Videos

A Multimodal Wide-Field Fourier-Transform Raman Microscope
06:48

A Multimodal Wide-Field Fourier-Transform Raman Microscope

Published on: December 30, 2025

AMEBaS: Automatic Midline Extraction and Background Subtraction of Ratiometric Fluorescence Time-Lapses of Polarized Single Cells
06:03

AMEBaS: Automatic Midline Extraction and Background Subtraction of Ratiometric Fluorescence Time-Lapses of Polarized Single Cells

Published on: June 23, 2023

Related Experiment Videos

Last Updated: Jun 17, 2026

ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis
07:11

ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis

Published on: August 19, 2021

A Multimodal Wide-Field Fourier-Transform Raman Microscope
06:48

A Multimodal Wide-Field Fourier-Transform Raman Microscope

Published on: December 30, 2025

AMEBaS: Automatic Midline Extraction and Background Subtraction of Ratiometric Fluorescence Time-Lapses of Polarized Single Cells
06:03

AMEBaS: Automatic Midline Extraction and Background Subtraction of Ratiometric Fluorescence Time-Lapses of Polarized Single Cells

Published on: June 23, 2023

Area of Science:

  • Spectroscopy
  • Data Analysis
  • Numerical Methods

Background:

  • Spectroscopic data often contains statistical noise, hindering accurate analysis.
  • Traditional methods for noise reduction may lack robustness or require manual parameter tuning.
  • Cubic B-spline basis functions offer a flexible approach for data smoothing.

Purpose of the Study:

  • To develop a novel criterion for selecting the optimal Cubic B-spline fitting curve.
  • To effectively remove statistical noise from spectroscopic data.
  • To provide an automated and parameter-free method for data smoothing.

Main Methods:

  • Utilizing Cubic B-spline basis functions for data fitting.
  • Iteratively selecting smoothed curves with increasing knot numbers.
  • Applying a new criterion based on the minimum residual sum of squares (RSS) between adjacent curves.
  • Employing Reinsch's first condition for tie-breaking when multiple optimal curves exist.

Main Results:

  • The derived criterion effectively identifies optimum fitting curves for noise reduction.
  • The new method demonstrates superior performance compared to using minimum RSS alone.
  • The criterion automatically determines smoothing conditions without requiring initial parameters.
  • Satisfactory noise removal was achieved for experimental spectroscopic data.

Conclusions:

  • The novel criterion offers a simple and effective approach for noise reduction in spectroscopic data.
  • Cubic B-spline functions combined with the new criterion provide an automated solution for data smoothing.
  • This method enhances the reliability of spectroscopic data analysis by mitigating statistical noise.