Related Experiment Video
Updated: Jun 17, 2026

Multicolor Flow Cytometry-based Quantification of Mitochondria and Lysosomes in T Cells
Published on: January 9, 2019
Rapid, absolute, and simultaneous quantification of specific pathogenic strain and total bacterial cells using an
Lingling Yang1, Lina Wu, Shaobin Zhu
1Department of Chemical Biology, College of Chemistry and Chemical Engineering, The Key Laboratory for Chemical Biology of Fujian Province, Xiamen University, Xiamen 361005, China.
Abstract:
This paper describes a rapid and sensitive strategy for the absolute and simultaneous quantification of specific pathogenic strain and total bacterial cells in a mixture. A laboratory-built compact, high-sensitivity, dual channel flow cytometer (HSDCFCM) was modified to enable dual fluorescence detection. A bacterial cell mixture comprising heat-killed pathogenic Escherichia coli E. coli O157:H7 and harmless E. coli DH5alpha was used as a model system. Pathogenic E. coli O157:H7 cells were selectively labeled by red fluorescent probe via antibody-antigen interaction, and all bacterial cells were stained with membrane-permeable nucleic acid dye that fluoresces green. When each individual bacterium passes through the interrogating laser beam, E. coli O157:H7 emits both red and green fluorescence, while E. coli DH5alpha exhibits only green fluorescence. Because the fluorescence burst generated from each individual bacterial cell was easily distinguished from the background, accurate enumeration and consequently absolute quantification were achieved for both pathogenic and total bacterial cells. By using this strategy, accurate counting of bacteria at a density above 1.0 x 10(5) cells/mL can be accomplished with 1 min of data acquisition time after fluorescent staining. Excellent correlation between the concentrations measured by the HSDCFCM and the conventional plate-counting method were obtained for pure-cultured E. coli O157:H7 (R(2) = 0.9993) and E. coli DH5alpha (R(2) = 0.9998). Bacterial cell mixtures with varying proportions of E. coli O157:H7 and E. coli DH5alpha were measured with good ratio correspondence. We applied the established approach to detecting artificially contaminated drinking water samples; E. coli O157:H7 of 1.0 x 10(2) cells/mL were accurately quantified upon sample enrichment. It is believed that the proposed method will find wide applications in many fields demanding bacterial identification and quantification.
More Related Videos
11:11Flow Cytometric Analysis of Bimolecular Fluorescence Complementation: A High Throughput Quantitative Method to Study Protein-protein Interaction
Published on: August 15, 2013
09:57Characterizing Microbiome Dynamics – Flow Cytometry Based Workflows from Pure Cultures to Natural Communities
Published on: July 12, 2018