Implementation of a closed-loop reporting system for critical values and clinical communication in compliance with
Fritz F Parl1, Mandy F O'Leary, Allen B Kaiser
1Clinical Chemistry Laboratory, Department of Pathology, TVC 4918, Vanderbilt University Medical Center, Nashville, TN 37232, USA. fritz.parl@vanderbilt.edu
Background:
Current practices of reporting critical laboratory values make it challenging to measure and assess the timeliness of receipt by the treating physician as required by The Joint Commission's 2008 National Patient Safety Goals.
Methods:
A multidisciplinary team of laboratorians, clinicians, and information technology experts developed an electronic ALERTS system that reports critical values via the laboratory and hospital information systems to alphanumeric pagers of clinicians and ensures failsafe notification, instant documentation, automatic tracking, escalation, and reporting of critical value alerts. A method for automated acknowledgment of message receipt was incorporated into the system design.
Results:
The ALERTS system has been applied to inpatients and eliminated approximately 9000 phone calls a year made by medical technologists. Although a small number of phone calls were still made as a result of pages not acknowledged by clinicians within 10 min, they were made by telephone operators, who either contacted the same physician who was initially paged by the automated system or identified and contacted alternate physicians or the patient's nurse. Overall, documentation of physician acknowledgment of receipt in the electronic medical record increased to 95% of critical values over 9 months, while the median time decreased to <3 min.
Conclusions:
We improved laboratory efficiency and physician communication by developing an electronic system for reporting of critical values that is in compliance with The Joint Commission's goals.
Related Concept Videos
Types of Reports I: Hand-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
Introduction to Documentation and Reporting
Nursing documentation records essential information and details regarding a patient's care and treatment in written or electronic form. It is a critical aspect of nursing practice that involves documenting assessments, interventions, outcomes, and other relevant details about a patient's health status.
Documentation maps the patient's health journey by creating a comprehensive and precise...
Types of Reports II: Incident or Occurrence Report
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
Types of Reports III: Telephone and Verbal Reports
Here's an overview of each type:
Telephone Orders
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include: