Multi-Modal Home Sleep Monitoring in Older Adults
Published on: January 26, 2019
Towards using photo-plethysmogram amplitude to measure blood pressure during sleep
Eric Chern-Pin Chua1, Stephen J Redmond, Gary McDarby
1School of Electrical, Electronic and Mechanical Engineering, University College Dublin, Belfield, Dublin 4, Ireland.
Abstract:
There is considerable interest in non-intrusive and reliable continuous ambulatory blood pressure measurement systems. Pulse amplitude is the peak to trough amplitude of the photo-plethysmogram signal. We compared pulse amplitude with a currently popular parameter, the pulse arrival time (PAT), for estimating continuous systolic blood pressure (SBP). Overnight sleep data from 18 young, healthy subjects (14 M 4 F, age 24+/-5 years, BMI 23.8+/-4.0 kg/m2) was analyzed. We found that pulse amplitude was more effective than PAT for estimating SBP during sleep. Mean coherence between pulse amplitude and SBP was significantly stronger than that for PAT [p<0.001, 95% CI: 0.21-0.25 (finger), 0.11-0.14 (wrist)]. Correlation between pulse amplitude and SBP was significantly stronger than that for PAT [p<0.001, 95% CI: 0.46-0.53 (finger), 0.13-0.20 (wrist)]. SBP estimation errors were significantly lower using pulse amplitude [p<0.001, 95% CI: -1.55 to -1.29 mmHg (finger), -0.53 to -0.36 mmHg (wrist)]. We also found that while pulse amplitude was closely related to SBP, the relationship weakened during and around REM sleep (ANOVA of REM, transitional Wake-REM and transitional REM-Sleep versus other sleep states: F=24.7, p<0.001). These results suggest that pulse amplitude is potentially a more suitable measure than pulse arrival time for estimating continuous blood pressure.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)