Related Experiment Video
Updated: Jun 17, 2026

Resonance Fluorescence of an InGaAs Quantum Dot in a Planar Cavity Using Orthogonal Excitation and Detection
Published on: October 13, 2017
Quantum dot infrared photodetector enhanced by surface plasma wave excitation
S C Lee1, S Krishna, S R J Brueck
1Center for High Technology Materials and Department of Electrical and Computer Engineering, University of New Mexico, 1313 Goddard SE, Albuquerque, NM 87106, USA. sclee@chtm.unm.edu
Abstract:
Up to a thirty-fold detectivity enhancement is achieved for an InAs quantum dot infrared photodetector (QDIP) by the excitation of surface plasma waves (SPWs) using a metal photonic crystal (MPC) integrated on top of the detector absorption region. The MPC is a 100 nm-thick gold film perforated with a 3.6 microm period square array of circular holes. A bare QDIP shows a bias-tunable broadband response from approximately 6 to 10 microm associated with the quantum confined Stark (QCS) effect. On the other hand, an MPC-integrated QDIP exhibits a dominant peak at 11.3 microm with a approximately 1 microm full width at half maximum and the highly enhanced detectivity at the bias polarity optimized for long wavelength. This is very different from the photoresponse of the bare QDIP but fully consistent with the direct coupling of the QDs in the detector absorption region to the SPWs excited at the MPC/detector interface by incident photons. The SPW resonance wavelength, lambda, for the smallest coupling wavevector of the array in the MPC is close to 11.3 microm. The response also shows other SPW-coupled peaks: a significant peak at 8.1 microm (approximately lambda/radical2) and noticeable peaks at 5.8 microm (approximately lambda/2) and 5.4 microm (approximately lambda/ radical5) which correspond to higher-order coupling wavevectors. For the opposite bias, the MPC-integrated QDIP shows the highest response at 8.1 microm, providing a dramatic voltage tunability that is associated with QCS effect. SPWs propagate with TM (x, z) polarization along the MPC/detector interface. The enhanced detectivity is explained by these characteristics which increase both the effective absorption cross section with propagation and the interaction strength with TM polarization in the coupling to the QDs. Simulations show good qualitative agreement with the observed spectral behavior.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Gas Chromatography: Types of Detectors-II

