Related Experiment Video
Updated: Jun 17, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Compressing the non-dependent lung during one-lung ventilation improves arterial oxygenation, but impairs systemic
Seiji Ishikawa1, Madoka Shirasawa, Michiko Fujisawa
1Department of Anesthesiology, Graduate School of Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8519, Japan. ishikawa.mane@tmd.ac.jp
Purpose:
We have previously found that compression of the non-dependent lung improves arterial oxygenation during one-lung ventilation (OLV) in patients undergoing esophagectomy. The purpose of this study was to investigate the effects of compression of the non-dependent lung on hemodynamic indices and oxygen delivery using a minimally invasive cardiac output (CO) monitor.
Methods:
Sixteen consecutive patients undergoing esophagectomy through a right thoracotomy were studied. Under general anesthesia, a left-sided double-lumen tube was placed for OLV, and the dependent lung was mechanically ventilated with a tidal volume of 8 ml kg(-1) body weight and a fraction of inspiratory oxygen of 0.8 during OLV. CO was monitored continuously using a FloTrac/Vigileo (Edwards Lifesciences) system. Surgeons compressed the non-dependent lung several times during surgery using a lung retractor to improve exposure of the surgical field. The oxygen delivery index was roughly estimated as the product of the cardiac index (CI) and arterial oxygen saturation as monitored by pulse oximetry (Spo2).
Results:
Just before non-dependent lung compression, mean (+/- SD) CI and Spo2 were 2.6 +/- 0.6 L min(-1) m(-2) and 95.0 +/- 3.9%, respectively. At 1 min after non-dependent lung compression, Spo2 increased significantly to 97.8 +/- 2.2% (P < 0.05), but CI decreased significantly to 2.0 +/- 0.4 L min(-1) m(-2) (P < 0.05). The product of CI and Spo2 at 1 min was significantly lower (192.7 +/- 37.3) than baseline levels (250.5 +/- 66.3, P < 0.05).
Conclusion:
Although non-dependent lung compression may be a potentially effective measure to treat hypoxemia during OLV, it should be noted that CO and systemic oxygen delivery may be decreased by this maneuver.
Related Concept Videos
Atelectasis II: Pathophysiology
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Transport in the Blood
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...