Related Experiment Video
Updated: Jun 17, 2026

Atomic Force Microscopy Measurements of Cartilage in Intact and Regenerating Axolotl Limbs
Published on: October 11, 2024
Viscoelasticity of the alar and transverse ligaments
J Möller1, L P Nolte, H Visarius
1Department of Orthopaedic Surgery, St. Josef Hospital, Ruhr University Bochum, Federal Republic of Germany.
Abstract:
The occipito-atlanto-axial joint is the most complex one of the human spine. Traumatic or inflammatory lesions in this region may lead to instability and neurological symptoms of clinical importance. This study reports the results of anatomical and biomechanical examination of 13 human upper cervical spine specimens and focuses on the viscoelastic behavior of the alar and transverse ligaments. Non-destructive tensile testing was performed on a uniaxial testing machine with 25 alar and 11 transverse ligaments at three different load rates of 0.1 mm/s, 1.0 mm/s, and 10.0 mm/s. The ligaments were further tested for relaxation over 300s. Each ligament exhibited an initial neutral zone in which no tensile force could be measured during cyclic testing. This neutral zone was more significant in the alar ligaments than in the transverse ligaments with respect to the measured in situ length of the ligaments (11.2 vs 18.1 mm on average). Increasing axial deformation led to increased load in all ligaments. Hysteresis, i.e., the energy loss exhibited by viscoelastic material subjected to loading and unloading cycles, increased with higher displacement rates and higher tensile forces. In neutral position the alar ligaments were lax in all specimens. During axial rotation both alars tightened. Ligamentous resistance increased as the end of the range of motion (ROM) was approchaed during rotation. The neutral zone explains the laxity of the ligaments in midposition and allows mobility of the upper cervical spine with minimum expenditure of muscular energy. The ligaments become stiffer under higher loads and therefore contribute to a limitation of the ROM in the occipitio-atlanto-axial joint.
Related Concept Videos
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Elastin is Responsible for Tissue Elasticity
Ligaments and tendons are made of dense regular connective tissue, but in ligaments not all fibers are parallel. Dense regular elastic tissue contains elastin fibers and...
Deformations in a Transverse Cross Section
As the material stretches, it expands or contracts in orthogonal directions to the load. This phenomenon varies...
Strain and Elastic Modulus
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Bending and Torsional Moments
The reaction developed in a structural element when subjected to an external force causes the element to bend. When a structural element bends upwards, it creates compressive normal forces on the top and tensile normal forces on the bottom, resulting in a couple that determines the bending...
