Coulomb-controlled single electron field emission via a freely suspended metallic island

Chulki Kim1, Hyun S Kim, Hua Qin

  • 1Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA. ckim4@wisc.edu

Nano Letters
|January 12, 2010
PubMed

Related Concept Videos

Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential ensures...
Electric Field at the Surface of a Conductor01:26

Electric Field at the Surface of a Conductor

Consider a conductor in electrostatic equilibrium. The net electric field inside a conductor vanishes, and extra charges on the conductor reside on its outer surface, regardless of where they originate.
In the 19th century, Michael Faraday conducted the famous ice pail experiment to prove that the charges always reside on the surface of a conductor. The experimental set-up consists of a conducting uncharged container mounted on an insulating stand. The outer surface of the container is...
Biasing of Metal-Semiconductor Junctions01:27

Biasing of Metal-Semiconductor Junctions

Biasing metal-semiconductor junctions involves applying a voltage across the junction. Specifically, the metal is connected to a voltage source, while the semiconductor is grounded. This technique is essential for controlling the direction and magnitude of current flow in electronic devices, including diodes, transistors, and photovoltaic cells.
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
Metal-Semiconductor Junctions01:24

Metal-Semiconductor Junctions

The contact of metal and semiconductor can lead to the formation of a junction with either Schottky or Ohmic behavior.
Schottky Barriers
Schottky barriers arise when a metal with a work function (Φm) contacts a semiconductor with a different work function (Φs). Initially, electrons transfer until the Fermi levels of the metal and semiconductor align at equilibrium. For instance, if Φm > Φs, the semiconductor Fermi level is higher than the metal's before contact. The semiconductor's...
Induced Electric Fields01:23

Induced Electric Fields

The fact that emfs are induced in circuits implies that work is being done on the conduction electrons in the wires. What can possibly be the source of this work? We know that it’s neither a battery nor a magnetic field, as a battery does not have to be present in a circuit where current is induced, and magnetic fields never do any work on moving charges. The source of the work is in fact an electric field that is induced in the wires. For example, if a stationary conductor is placed in a...