Related Experiment Video
Updated: Jun 17, 2026

Establishment and Evaluation of a Porcine Vein Graft Disease Model
Published on: July 25, 2022
Prevention of primary vascular graft infection with silver-coated polyester graft in a porcine model
1Vascular Research Unit, Department of Vascular Surgery, Regional Hospital Viborg, Viborg, Denmark. gao.hong@viborg.rm.dk
Objectives:
To evaluate the efficacy of a silver-coated vascular polyester graft in the prevention of graft infection after inoculation with Staphylococcus aureus in a porcine model.
Material And Methods:
Eighty-four pigs were randomly selected 1:1 to receive a silver-coated or non-silver-coated 8-mm-wide polyester graft implanted end-to-end in the infrarenal aorta. At the end of implantation, 10(6) colony forming units (CFUs) S. aureus in 0.3ml suspension were inoculated directly on the graft surface. Blood samples assayed for white blood corpuscles (WBCs) and C-reactive protein (CRP) were taken before implantation and on the postoperative days 2, 5, 7, 11 and 14. Two weeks after implantation, the perigraft swabs were analysed for S. aureus or contaminants. CFUs of S. aureus were quantified and logarithmised. Student's t-tests, repeated measurement analysis of variance (ANOVA) and chi-square test were employed to compare the two grafts.
Results:
All pigs developed graft infection. There were no statistically significant differences between the silver-coated and non-silver-coated grafts in the quantity of S. aureus, macroscopic signs of infection and postoperative changes in the temperature, WBC and CRP.
Conclusions:
Silver-coated polyester grafts failed to prevent graft infections after inoculation with 10(6)S. aureus in 0.3ml suspension in a porcine model.