Sensitivity to change of cartilage morphometry using coronal FLASH, sagittal DESS, and coronal MPR DESS
W Wirth1, M Nevitt, M-P Hellio Le Graverand
1Chondrometrics GmbH, Ainring, Germany. wolfgang.wirth@pmu.ac.at
Osteoarthritis and Cartilage
|January 12, 2010
Summary
Quantitative MRI protocols for knee osteoarthritis (OA) show similar sensitivity to cartilage thickness changes over time. Analyzing every second DESS MRI slice is sufficient for tracking OA progression, aiding biomarker discovery.
Area of Science:
- Biomedical Imaging
- Osteoarthritis Research
- Quantitative MRI
Background:
- The Osteoarthritis Initiative (OAI) seeks biomarkers for knee osteoarthritis (OA) onset and progression.
- Current quantitative cartilage imaging uses Fast Low Angle Shot (FLASH) and Double Echo Steady-State (DESS) sequences.
- FLASH sequences have long acquisition times, while DESS offers near-isotropic resolution.
Purpose of the Study:
- To directly compare the sensitivity to cartilage thickness changes between FLASH and DESS MRI protocols.
- To evaluate the longitudinal correlation of cartilage thickness measurements from these protocols.
- To assess the utility of reduced DESS data (every second slice) for OA progression monitoring.
Main Methods:
- Acquired baseline and 12-month follow-up MRI data from 80 knees using 1.5 mm coronal FLASH and 0.7 mm sagittal DESS sequences.
- Performed cartilage segmentation on FLASH, sagittal DESS (sagDESS), and coronal multi-planar reconstructions (MPR) of DESS.
- Analyzed cartilage thickness changes in specific weight-bearing regions of the medial femorotibial compartment.
Main Results:
- Standardized response means (SRMs) for cartilage thickness change were comparable across FLASH, coronal MPR DESS, and sagDESS protocols.
- SRMs ranged from -0.34 (coronal FLASH) to -0.38 (sagDESS, 75% ROI), indicating similar sensitivity to change.
- High baseline correlations (r >= 0.94) and moderate-to-high longitudinal correlations (Pearson >= 0.79, Spearman >= 0.45) were observed between protocols.
Conclusions:
- Both FLASH and DESS MRI techniques demonstrate similar longitudinal sensitivity for assessing cartilage morphometry changes in knee OA.
- Analyzing every second slice of the 0.7 mm DESS sequence provides adequate sensitivity for detecting cartilage thickness changes.
- These findings support the use of DESS MRI, potentially with reduced data acquisition, for efficient OA progression monitoring in large cohorts like OAI.