Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Influence of stationary phase chemistry and mobile-phase composition on retention, selectivity, and MS response in
Kenneth J Fountain1, Jane Xu, Diane M Diehl
1Waters Corporation, Milford, MA 01757, USA. kenneth_fountain@waters.com
Abstract:
A comprehensive retention and selectivity characterization of several hydrophilic interaction chromatography (HILIC) stationary phases was performed with 28 test probes in order to study the influence of particle type, surface chemistry, and mobile-phase pH on chromatographic retention, selectivity, and MS response. Selectivity differences were compared for columns operated at both low and high pH, while ESI-MS was used to study the effects of mobile-phase pH on signal response. Additionally, acetone was explored as a potential alternative to ACN as the weak HILIC solvent. Moderate differences in selectivity were observed on the same column operated at different pH, mostly due to acidic compounds. In addition, the MS response increased when a high pH mobile phase was used, particularly for analytes that were ionized with negative ESI-MS. Even larger selectivity differences were observed for different stationary phases evaluated with the same mobile phase. Acetone was not a suitable replacement for ACN in routine HILIC separations due to differences in selectivity and MS response. Finally, the data from this study were used to establish guidelines for rapid HILIC method development of polar compounds, which is demonstrated with a mixture of histidine dipeptides and organophosphonate nerve agent metabolites.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Analyte Adsorption and Distribution
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Elution Process
Chromatographic Methods: Terminology