Related Experiment Video
Updated: Jun 17, 2026

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
Published on: May 2, 2018
Response of alanine and barium dithionate EPR dosimeters
V A Onischuk1, J de Boer, A I Levon
1Institute for Nuclear Research, Kiev, Ukraine. onischuk@kinr.kiev.ua
Abstract:
The response of alanine and barium dithionate EPR dosimeters to proton irradiation with energies ranging from 6.6-25 MeV has been investigated. EPR dosimeters were calibrated using calibrated gamma sources. Alanine dosimeters show a value 29% higher than those obtained by a Markus chamber at the same energy, and barium dithionate shows a value 22% smaller. The response of the EPR dosimeters to irradiation at a mean dose of about 40 Gy depends on the proton energy. Using experimental data, the yield of the radicals in the tracks for the alanine pellets was calculated. The yield of the radicals was determined to be proportional to the linear energy transfer (LET) on the straight-line length of the proton track, and the proportional coefficient for alanine is equal to 0.109 eV-1. In the area of the Bragg peak, the probability of recombination of the ionized electrons with cations is increased. As a result, approximately 4.6 MeV of proton energy is used for ionization that results in electron-cation recombination instead of formation of radicals, and maximum LET does not coincide with the maximum concentration of the radicals.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
12:02Determination of Thermodynamic Properties of Alkaline Earth-liquid Metal Alloys Using the Electromotive Force Technique
Published on: November 3, 2017
Related Concept Videos
EDTA: Indirect and Alkalimetric Titration
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Biological Effects of Radiation
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...