Related Experiment Video
Updated: Mar 24, 2026

Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026
Unstable distal radius fractures in the elderly patient--volar fixed-angle plate osteosynthesis prevents secondary
Markus Figl1, Patrick Weninger, Josef Jurkowitsch
1Lorenz Boehler Trauma Center, Donaueschingenstrasse 13, A-1200 Vienna, Austria. m.figl@gmx.at
Background:
Because of demographic changes in industrialized countries, signifying a growing population of the aged and a markedly increased life expectancy, the incidence of the distal radius fracture is expected to increase by a further 50% until the year 2030. Osteoporosis characterizes the radius fracture in elderly patients. Primarily weakening metaphyseal bone, osteoporosis renders simple fractures unstable and makes distal bone fixation a challenge. The introduction of fixed-angle plate systems for extension fractures of the radius was evaluated in a prospective study performed at our hospital after selection and acquisition of a new plating system. The focus of our interest was whether a secondary loss of reduction can be prevented by this plating system in the elderly patient.
Methods:
We reviewed 58 patients aged 75 years or older treated for unstable distal radius fractures using a volar fixed-angle plate. Postoperative management included immediate finger motion, early functional use of the hand, wrist splint used for 4 weeks, and physiotherapy. At the time of follow-up, after a mean period of 13 months (range, 12-15 months), standard radiographic and clinical fracture parameters were measured and final functional results were assessed.
Results:
Bone healing had occurred in all patients at the time of follow-up. On X-rays taken at the time of follow-up, 53 patients (91%) had no radial shortening, 5 patients (9%) had a mean radial shortening occurred during follow-up of only 1.3 mm (range, 1-2 mm) compared with the contralateral side. Comparing the first postoperative X-rays with those taken at final evaluation showed no measurable loss of reduction in the volar tilt or radial inclination. Castaing's score yielded a perfect outcome in 25 cases, a good outcome in 30 cases, and an adequate outcome in 3 cases. On an average, the range of motion was reduced by 19% during extension/flexion, by 13% during radial/ulnar deviation, and by 9% in pronation/supination compared with the contralateral side. Grip strength was 55% higher than that of the contralateral side. Eleven patients (19%) reported pain at rest with a mean Visual Analog Pain Scale score of 3.1 (range, 1-6), whereas 30 patients (52%) had pain on load-bearing with a mean Visual Analog Pain Scale score of 3.4 (range, 1-8). The mean disabilities of the arm, shoulder, and hand (DASH) score (Jester A, Harth A, Germann G. J Hand Surg Am. 2005;30:1074.e1-1074.e10) was 28 points. A carpal tunnel syndrome with abnormal nerve conduction velocity was diagnosed in three patients, a rupture of the flexor pollicis longus tendon was seen in one patient.
Conclusion:
Fixed-angle plate osteosynthesis at the distal radius in the elderly patient signifies a significant improvement in the treatment of distal radial fractures in terms of restoration of the shape and function of the wrist associated with a low complication rate. This technique with its simple palmar access, allows exact anatomic reduction of the fracture, allows early return to function, and minimizes morbidity in the elderly patient. Secondary correction loss can be prevented by this procedure.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...