Abstract:
THIOMABs are antibodies with an engineered unpaired cysteine residue on each heavy chain that can be used as intermediates to generate antibody-drug conjugates. Multiple charge variant peaks were observed during cation-exchange chromatography (CEX) and imaged capillary isoelectric focusing (cIEF) analysis of several different THIOMABs. This charge heterogeneity was due to cysteinylation and/or glutathionylation at the engineered and unpaired cysteines through disulfide bonds formed during the cell culture process. Cysteine treatment followed by analysis using CEX, LC/MS and electrophoresis demonstrates that cysteine is a mild reductant that can remove glutathione and cysteine bound to the engineered cysteines without disrupting the inter- or intra-chain disulfide bonds of antibodies. We further demonstrated that using a cysteine/cystine redox pair (rather than cysteine alone) can not only effectively remove glutathione at the engineered cysteines, but also generate homogeneously cysteinylated species, which resulted in one main peak in both CEX-HPLC and imaged cIEF assays for antibodies with engineered and unpaired cysteines.