Procedures for determining the spectral responsivity of an infrared radiometer
Abstract:
With the increasing number of commercial radiometers employing rather varied and sophisticated optical designs, the determination of the spectral responsivity of these radiometers has accordingly become more involved. A joint National Bureau of Standards-U. S. Army (Missile Electronics Warfare Technical Area, White Sands Missile Range, New Mexico) calibration of an ir radiometer was conducted at the White Sands Missile Range facility. The radiometer chosen for the measurements employed an uncooled PbS detector with a 10-cm Cassegrainian optical system. The selection of this particular type of instrument permitted two methods of measurement (each employing different standards and techniques) to be investigated. In order to simulate infinitely distant point sources, a 30-cm off-axis collimator was used in both methods of calibration. The methods of calibration and the uncertainties associated with each method are described and the application of the responsivity values to field measurements is discussed. The agreement of the spectral responsivity values as determined by each method is within the estimated uncertainty computed for each procedure.
More Related Videos
09:18Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
09:36The Use of High-resolution Infrared Thermography (HRIT) for the Study of Ice Nucleation and Ice Propagation in Plants
Published on: May 8, 2015
Related Concept Videos
IR Spectrometers
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
UV–Vis Spectrometers