Paediatric CT reference doses based on weight and CT dosimetry phantom size: local experience using a 64-slice CT
Debbie J Watson1, Kerry S Coakley
1Medical Imaging, Royal Children Hospital, Level 2, Foundation Building, Herston Rd, Herston, Brisbane, Queensland, 4029, Australia. debbie_watson@health.qld.gov.au
New Australian guidelines establish local dose reference levels (LDRLs) for paediatric CT scans, presented by weight. These LDRLs aid in monitoring radiation dose and ensuring quality patient care.
Area of Science:
- Medical Imaging Physics
- Radiological Protection
- Paediatric Radiology
Background:
- Technological advancements necessitate updated dose reference levels (DRLs) for CT examinations.
- Australian legislation promotes establishing local DRLs (LDRLs) to monitor CT performance and patient dose.
- Existing DRLs may not reflect current imaging technology.
Purpose of the Study:
- To establish paediatric DRL values in a clinically applicable format, stratified by patient weight.
- To reference these DRLs using both 16-cm and 32-cm CT dosimetry phantoms.
- To report local experience with LDRLs and compare them with published paediatric DRL data.
Main Methods:
- Retrospective analysis of 1382 paediatric CT examinations.
- Utilized CT dose index volume (CTDIvol) and dose length product (DLP) data from a Toshiba Aquilion 64 scanner.
- Compiled LDRLs based on weight and phantom size for torso and head examinations.
Main Results:
- Local DRLs (LDRLs) were successfully compiled for paediatric torso examinations using 16-cm and 32-cm phantoms.
- LDRLs for paediatric head examinations were established using the 16-cm phantom.
- The compiled LDRLs provide a benchmark for clinical practice at the Royal Children's Hospital (RCH) Brisbane.
Conclusions:
- LDRLs were established for the RCH Brisbane, offering a valuable reference for clinicians.
- Comparison of these LDRLs with published data serves as a quality assurance measure.
- This approach facilitates adherence to updated radiation dose monitoring recommendations.