Related Experiment Video
Updated: Jun 17, 2026

Quantifying Infra-slow Dynamics of Spectral Power and Heart Rate in Sleeping Mice
Published on: August 2, 2017
Evoked response of heart rate variability using short-duration white noise
Guo-She Lee1, Mei-Ling Chen, Gin-You Wang
1School of Medicine, National Yang-Ming University, Taipei, Taiwan.
Abstract:
To investigate and to establish a model for evaluation of the instant cardiovascular responses to the noises of low-to-moderate intensity, sixteen healthy subjects were enrolled. The white noises were binaurally presented with a supra-aural earphone. The test intensities of noises were no noise, 50, 60, 70 and 80 dBA. Each noise was continued for 5 min and the electrocardiogram was simultaneously recorded. The cardiac autonomic responses were evaluated using power spectral analysis of the R-R contour obtained from digital signal processing of the ECG tracings. The result showed that the mean heart rate and mean blood pressure did not change significantly with the noises. However, the low-frequency power (LF) which represents cardiac autonomic modulations and the ratio (LHR) of LF to high-frequency power (HF) which reflects cardiac sympathetic modulations were significantly greater in the noise intensity of 50, 60, 70 and 80dBA (p<0.01, repeated measures ANOVA). In addition, the LHR was significantly correlated with the noise intensity (rho=0.90, p<0.05, Spearman's correlation analysis). The instant autonomic responses to white noises can be detected using power spectral analysis of heart rate variability and the evoked responses may provide a sensitive way to evaluate the instant effect of noise to humans.
More Related Videos
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...

