Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
An energy-dispersive technique to measure x-ray coherent scattering form factors of amorphous materials
1Ottawa Medical Physics Institute and Department of Physics, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6, Canada. Brian.King@newcastle.edu.au
Abstract:
The material-dependent x-ray scattering properties of amorphous substances such as tissues and phantom materials used in imaging are determined by their scattering form factors, measured as a function of the momentum transfer argument, x. Incoherent scattering form factors, F(inc), are calculable for all values of x while coherent scattering form factors, F(coh), cannot be calculated except at large x because of their dependence on long-range order. As a result, measuring F(coh) is very important to the developing field of x-ray scatter imaging. Previous measurements of F(coh), based on crystallographic techniques, have shown significant variability, as these techniques are not optimal for amorphous materials. We have developed an energy-dispersive technique that uses a polychromatic x-ray beam and an energy-sensitive detector. We show that F(coh) can be measured directly, with no scaling parameters, by computing the ratio of two spectra: the first, measured at a given scattering angle and the second, the direct transmission spectrum with no scattering. Experiments have been constructed on this principle and used to measure F(coh) for water and polyethylene to explore the reliability of the technique. A 121 kVp x-ray spectrum and seven different scattering angles between 1.67 and 15.09 degrees were used, resulting in a measurable range of x between 0.5 and 9.5 nm(-1). These are the first measurements of F(coh) made without the need for a scaling factor. Resolution in x varies between 10% for small scattering angles and 2% for large scattering angles. Accuracy in F(coh) is shown to be strongly dependent on the precision of the experimental geometry and varies between 5% and 15%. Comparison with previous published measurements for water shows values of the average absolute relative difference between 8% and 14%.
More Related Videos
08:44Measurements of Long-range Electronic Correlations During Femtosecond Diffraction Experiments Performed on Nanocrystals of Buckminsterfullerene
Published on: August 22, 2017
08:53Biochemical and Structural Characterization of the Carbohydrate Transport Substrate-binding-protein SP0092
Published on: October 2, 2017
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Determination of Crystal Structures
Atomic Emission Spectroscopy: Overview
Atomic Fluorescence Spectroscopy
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.