Related Experiment Video
Updated: Jun 17, 2026

10:42
Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Near infrared reflection spectra of artificial cumulus clouds
Applied Optics
|January 15, 2010
Summary
This study analyzes artificial cumulus cloud reflection spectra across various droplet sizes. Larger droplet sizes in clouds correlate with deeper reflectivity minima, matching natural cloud observations.
Area of Science:
- Atmospheric Science
- Cloud Physics
- Spectroscopy
Background:
- Understanding cloud radiative properties is crucial for climate modeling.
- Cumulus clouds significantly influence Earth's energy balance.
- Spectral analysis provides insights into cloud microphysical properties.
Purpose of the Study:
- To investigate the spectral reflectivity of artificial cumulus clouds.
- To determine the influence of droplet size on cloud reflectivity.
- To compare artificial cloud spectra with natural terrestrial cloud spectra.
Main Methods:
- Generating artificial cumulus cloud models with varying droplet sizes.
- Measuring reflection spectra from 1.0 to 2.4 micrometers.
- Applying corrections for gaseous absorption in spectral data.
Main Results:
- Identified distinct reflectivity minima at 1.16, 1.41, and 1.92 micrometers.
- Observed that reflectivity minima deepen progressively with increasing droplet size.
- Demonstrated strong agreement between artificial and natural terrestrial cloud reflection spectra.
Conclusions:
- Droplet size is a key factor determining the spectral reflectivity of cumulus clouds.
- Artificial cloud models can accurately replicate the spectral characteristics of natural clouds.
- The findings support the use of spectral reflectivity for remote sensing of cloud properties.
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
Infrared (IR) Spectroscopy: Overview
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
IR Spectrum
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
IR Frequency Region: Fingerprint Region
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the C=O, C=N, and C=C occur between 1600–1850 cm−1.
The...
The...
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
IR Spectroscopy: Molecular Vibration Overview
When Infrared (IR) radiation passes through a covalently bonded molecule, the bonds transition from lower to higher vibrational levels. The fundamental vibrational motions that result in infrared absorption can be classified as stretching or bending vibrations.
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...

