Emission Spectroscopic Boundary Layer Investigation during Ablative Material Testing in Plasmatron
Published on: June 9, 2016
12.6K
Etalonnage absolu d'un spectrometre SISAM.
Applied Optics
|January 16, 2010
Summary
A SISAM spectrometer was calibrated for precise absolute wavelength measurements. The new apparatus achieved high accuracy, crucial for spectroscopic analysis.
Area of Science:
- Spectroscopy
- Optical Metrology
- Atomic Physics
Background:
- Accurate wavelength measurements are fundamental in various scientific disciplines.
- Existing methods may have limitations in precision or scope.
- The development of advanced spectroscopic instruments is ongoing.
Purpose of the Study:
- To calibrate a SISAM spectrometer for absolute wavelength determination.
- To implement and test a novel apparatus utilizing Fabry-Perot fringes.
- To evaluate the performance and accuracy of the developed system.
Main Methods:
- Adjustment and configuration of a SISAM (Self-Ionization Spectroscopy Analysis Method) spectrometer.
- Integration of a Fabry-Perot interferometer setup for fringe analysis.
- Utilized emission lines for calibration and wavelength determination.
Main Results:
- The apparatus function width was determined to be less than 0.025 cm⁻¹.
- A relative accuracy of 0.003 cm⁻¹ was achieved for wavelength measurements.
- The results demonstrate the effectiveness of the Fabry-Perot based method.
Conclusions:
- The calibrated SISAM spectrometer provides high-precision absolute wavelength measurements.
- The developed apparatus offers a significant improvement in accuracy for spectroscopic applications.
- This work contributes to advancements in optical metrology and precision spectroscopy.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
857
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
857
Atomic Absorption Spectroscopy: Instrumentation
1.3K
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
1.3K
Atomic Absorption Spectroscopy: Overview
2.9K
Atomic absorption spectroscopy (AAS) is a technique used to analyze elements by measuring electromagnetic radiation (EMR) absorbed by atoms, which causes them to transition to a higher-energy orbit. The most crucial step in AAS is atomization, where the analyte is converted into gas-phase atoms, typically through a flame or furnace. Some of these atoms become thermally excited in the flame, while most remain in the ground state.
When irradiated by EMR of a particular wavelength, these...
When irradiated by EMR of a particular wavelength, these...
2.9K
UV–Vis Spectrometers
2.6K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
2.6K
Atomic Absorption Spectroscopy: Interference
1.7K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
1.7K
Atomic Emission Spectroscopy: Lab
402
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
402