Impact of endotracheal tube size on preextubation respiratory variables
Sangeeta Mehta1, Matthew J Heffer, Nava Maham
1Division of Respirology and Interdepartmental Division of Critical Care Medicine, Department of Internal Medicine, Mount Sinai Hospital and University of Toronto, Toronto, Ontario, Canada. geeta.mehta@utoronto.ca
Purpose:
Many parameters have been evaluated to predict successful extubation. These are all affected by extrapulmonary variables. The purpose of this study was to evaluate the effect of endotracheal tube (ETT) size on preextubation predictors of successful extubation.
Materials And Methods:
Twenty-two intubated and mechanically ventilated subjects were recruited when ready for extubation. Subjects were ventilated with T-piece, continuous positive airway pressure (CPAP) of 5 cm H(2)O, and pressure support ventilation (PSV) of 5 cm H(2)O in randomized order for 15 minutes each. Pulmonary mechanics-including respiratory frequency (f), tidal volume (V(T)), f/V(T) ratio, negative change in esophageal pressure, pressure time product (PTP), work of breathing, and the airway occlusion pressure 100 milliseconds after the onset of inspiratory flow-were measured using a microprocessor-based monitor at the end of each interval. After extubation, measurement of pulmonary mechanics was repeated at 15 and 60 minutes.
Results:
In patients with 7.0- or 7.5-mm ETT compared with patients with 8.0-mm ETT, (1) f was significantly higher during all ventilatory modes and 15 minutes after extubation; (2) V(T) during PSV and CPAP was significantly lower; (3) mean f/V(T) was significantly higher (122 ± 57 vs 69 ± 35, P = .026); and (4) PTP was significantly higher during CPAP, PSV, and 15 minutes after extubation. There was a nonsignificant trend toward increased negative change in esophageal pressure, work of breathing, and airway occlusion pressure 100 milliseconds after the onset of inspiratory flow in the smaller-ETT group.
Conclusions:
The ETT size has a significant impact on f, V(T), f/V(T) ratio, and PTP.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...