Related Experiment Video
Updated: Jun 17, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Correlation between breast density in mammography and background enhancement in MR mammography
1Department of Radiology, Maltepe University School of Medicine, Maltepe, Istanbul, Turkey. rahmicubuk@yahoo.com
Purpose:
We aimed to analyse the influence of mammographic breast density on background enhancement (BE) at magnetic resonance (MR) mammography in pre- and postmenopausal women. In addition, we questioned predictability of contrast-enhancement dynamics of normal fibroglandular tissue (NFT) at MR mammography according to mammographic breast density.
Materials And Methods:
Twenty-six patients (mean age 51.54+/-11.5 years; range 37-79 years) who underwent both MR mammography and conventional mammography were included in this retrospective study. Fourteen patients were premenopausal and 12 were postmenopausal. The ethics committee of our institution approved the study. The mammograms were retrospectively reviewed for overall breast density according to the four-point scale (I-IV) of the Breast Imaging Reporting and Data System (BI-RADS) classification. Two radiologists, who were unaware of the clinical data, separately assessed the MR mammography images. Images were assessed for enhancement kinetic features (enhancement kinetic curve and the early-phase enhancement rate) and BE. MR mammography and conventional mammography findings were compared according to BI-RADS breast density category and menopausal status.
Results:
Percentage of increased signal intensity values during the first minute did not change according to mammographic breast density, and the mean early-phase enhancement rate scores were similar among breast density groups (p=0.942). There was no significant difference between pre- and postmenopausal groups. Enhancement kinetic features of the different groups based on BI-RADS breast density category and menopausal status were similar. There was no correlation between breast density and BE in either premenopausal (p=0.211) or in postmenopausal (p=0.735) groups.
Conclusions:
We determined no correlation between mammographic breast density and so-called BE in MR mammography in either premenopausal or postmenopausal women. NFT at MR mammography cannot be predicted on the basis of mammographic breast density.
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies III: Computed Tomography