Background:
TEE is a semi-invasive tool broadly used and its utilization associated to sedatives drugs might to affect the procedure safety.
Objective:
to analyze aspects of TEE safety associated to the use of Midazolan (MZ) and Flumazenil (FL) and the influence of the clinical variables on the event rate.
Method:
prospective study with 137 patients that underwent TEE with MZ associated to moderate sedation. We analyzed the following events: complications related with the topical anesthesia, with MZ use and with the procedure. Uni- and multivariate analyses were used to test the influence of the clinical variables: age, sex, stroke, myocardiopathy (MP), duration of the test, mitral regurgitation (MR) and the MZ dose.
Results:
All patients (65+/-16 yrs; 58% males) finished the examination. The mean doses of MZ and FL were 4.3+/-1.9 mg and 0.28+/-0.2 mg, respectively. The duration of the examination and the mean ejection fraction (EF) were 16.4+/-6.1 minutes and 60+/-9%, respectively. Mild hypoxia (SO2<90%) was the most common event (11 patients); 3 patients (2%) presented transient hypoxia due to upper airway obstruction by probe introduction and 8 (5.8%) due to hypoxia caused by MZ use. Transient hypotension (SAP<90mmHg) occurred in 1 patient (0.7%). The multivariate analysis showed that severe MR, MP (EF<45%) and high doses of MZ (>5mg) were associated with events (p<0.001). The EF was 40%, in the group with MP and 44% in the group with severe MR and it can be a factor associated with clinical events in the last group.
Conclusion:
TEE with sedation presents a low rate of events. There were no severe events and there was no need to interrupt the examinations.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Imaging Studies for Cardiovascular System V: CT