Related Experiment Video
Updated: Jun 16, 2026

Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models
Published on: March 1, 2015
Evaluation of swallowing using 320-detector-row multislice CT. Part I: single- and multiphase volume scanning for
Naoko Fujii1, Yoko Inamoto, Eiichi Saitoh
1Department of Radiology, Fujita Health University School of Medicine, 1-98, Dengakugakubo, Kutsukake, Toyoake, Aichi, 470-1192, Japan. nfujii@fujita-hu.ac.jp
Abstract:
A 320-detector-row multislice computed tomography (320-MSCT) scanner can acquire a volume data set covering a maximum range of 16 cm and can generate axial images 0.5-mm thick at 0.5-mm intervals. Three-dimensional (3D) images reconstructed from the thin axial slices include multiplanar reconstruction and 3D-CT. Single-phase 3D images are reconstructed from 0.175-s data, and multiphase 3D images are created in 29 phases at intervals of 0.1 s. Continuous replay of these 3D images produces four-dimensional moving images. In order to determine the feasibility of the morphologic and kinematic analyses of swallowing using 320-MSCT, single-phase volume scanning was performed on three patients and multiphase volume scanning was performed on one healthy volunteer. The single-phase 3D images clearly and accurately showed the structures involved in swallowing, and the multiphase 3D images were able to show the oral stage to the early esophageal stage of swallowing, allowing a kinematic analysis of swallowing. We developed a reclining chair that allows scanning to be performed with the subject in a semisitting position, which makes swallowing evaluation by 320-MSCT applicable not only to research on healthy swallowing but also to the clinical examination of dysphagia patients.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies III: Computed Tomography
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies VI: Voiding Cystourethrography and Cystography