Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Simultaneous intraoperative measurement of cardiac output by thermodilution and transtracheal Doppler
L C Siegel1, D C Fitzgerald, R H Engstrom
1Department of Anesthesia, Stanford University School of Medicine, California.
Abstract:
Intraoperative measurement of cardiac output with transtracheal Doppler (DOP) was compared with that measured by thermodilution (TD). Cardiac output was measured simultaneously with both methods in 17 adult patients. For 86 pairs of measurements, the average difference between the two techniques was -0.21.min-1. This bias had a standard deviation of 1.71.min-1. The average of the absolute value of the difference between measurements made with the two techniques was 1.31.min-1, with a standard deviation of 1.11.min-1. The limits of agreement were -3.6 to 3.11.min-1. Linear regression yielded the following equation: DOP = 0.62 TD + 1.54 l.min-1 (r = 0.63). To evaluate the ability of transtracheal DOP to trend changes in cardiac output, the changes in cardiac output at sequential time points were compared for the two techniques. The average difference in the changes in cardiac output measured by the two techniques was 0.01.min-1. This bias had a standard deviation of 1.71.min-1. In conclusion, the transtracheal DOP technique did not reproduce the measurement of cardiac output by TD intraoperatively. Transtracheal DOP did not accurately trend changes in the TD measurement. These findings were obtained from patients with cardiovascular disease, and the conclusions may depend in part on the patient population and the investigators' experience with the transtracheal DOP technique.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...