Clinical evaluation of the Terumo Capiox FX05 hollow fiber oxygenator with integrated arterial line filter
Joseph Deptula1, Melinda Valleley, Kimberly Glogowski
1Department of Cardiothoracic and Vascular Surgery, Children's Hospital and Medical Center, Omaha, Nebraska, USA. jdeptula@childrensomaha.org
Abstract:
Perfusion techniques and equipment in pediatric open heart surgery have continued to focus on decreasing prime volumes and lowering surface areas of the cardiopulmonary bypass circuit. While this has improved drastically over the last 20 years, greater demand is being placed on the perfusionist to reduce the deleterious effects of bypass without compromising safety or efficiency. Specifically, manufacturers of disposable perfusion equipment have focused on providing pediatric perfusionists with oxygenators that provide the smallest prime and surface area possible while attempting to maximize performance. Recently,Terumo Cardiovascular has introduced the Capiox FX05, a neonatal hollow fiber oxygenator that includes an integrated arterial line filter. The FX05 provides a blood flow range of 0.1-1.5 L/min and a low priming volume of 43 mL. Additionally, it is coated with X Coating, a biocompatible, hydrophilic polymer surface coating that reduces platelet adhesion and protein denaturation. The purpose of this study was to test the FX05 for gas transfer, blood path resistance, and blood handling characteristics in a standardized clinical setting. Heat exchange coefficients were also calculated during the cooling and warming period. Other data analyzed includes bypass circuit prime volumes and initial patient hematocrit along with the total operative homologous blood donor exposures. In summary, the FX05 offers good gas exchange capabilities and a low pressure drop during normal cardiopulmonary bypass parameters along with the safety of an integrated arterial line filter. Furthermore, the FX05 with integrated filter allows a reduction in overall bypass prime volume and surface area while promoting the reduction of homologous blood transfusions, optimizing hemostasis.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Hemodialysis II: Procedure and Complications