Related Experiment Video
Updated: Jun 16, 2026

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Pulmonary gas exchange in anaesthetised horses mechanically ventilated with oxygen or a helium/oxygen mixture
F Staffieri1, S H Bauquier, P J Moate
1Section of Critical Care & Anesthesia, Department of Clinical Studies-New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, USA.
Reason For Performing Study:
It is unknown whether administration of gas-mixtures high in inspired fraction of oxygen (FiO2) under general anaesthesia may increase formation of pulmonary atelectasis and impair gas exchange.
Objective:
To evaluate the effects of different FiO2 on pulmonary gas exchange in isoflurane-anaesthetised horses breathing a helium/oxygen (He/O2) mixture.
Methods:
Thirty healthy mature horses were sedated with i.v. acepromazine (0.02 mg/kg bwt), detomidine (0.002 mg/kg bwt) and xylazine (02-0.4 mg/kg bwt). General anaesthesia was induced with i.v. 5% guaifenesin to effect, diazepam (0.1 mg/kg bwt) and ketamine (2 mg/kg bwt), and maintained with isoflurane. Fifteen horses (Group HX) were ventilated mechanically with gas mixtures of successively increasing FiO2 (0.25-030, 0.50-0.55, > 0.90), obtained by blending 02 with Heliox (70% He/30% O2). The other 15 horses (Group O) were ventilated immediately with 100% O2 (FiO2 > 0.90). After 20 min of ventilation at the different FiO2 levels in Group HX and after 60 min in Group O, PaO2 and PaCO2 were measured and the alveolar to arterial PO2 gradient (P(A-a)O2) was calculated. Data analysis included robust categorical regression with clustering on horse (P < 0.05).
Results:
Inhalation of a He/O2 mixture with FiO2 as low as 0.25-030 ensured adequate arterial oxygenation and was associated with a smaller P(A-a)O2 gradient than inhalation of pure O2 (P < 0.05). In Group HX, PaO2 increased with each rise in FiO2 and so did P(A-a)O2 (P < 0.05). The PaO2 was significantly lower and the P(A-a)O2 higher in Group O compared to Group HX at a FiOz >0.90 (P < 0.05).
Conclusions And Potential Relevance:
Administration of a He/O2 gas mixture low in FiO2 can better preserve lung function than ventilation with pure oxygen. A step-wise increase of FiO2 using a He/O2 gas mixture might offer advantages with respect to pulmonary gas exchange over an immediate exposure to 100% 2O2.
Related Concept Videos
Gas Exchange and Transport
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Respiration and Gaseous Exchange
Respiration involves the exchange of gases, especially oxygen (O2) and carbon dioxide (CO2), between the alveoli and body cells, a process facilitated by blood circulation. As a result, the cardiovascular system, which involves the...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Inhalational Anesthetics: Overview
Pulmonary Cycle: Exhalation