Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Probability of failure of the watershed algorithm for peak detection in comprehensive two-dimensional chromatography
Gabriel Vivó-Truyols1, Hans-Gerd Janssen
1Analytical-Chemistry Group, van't Hoff Institute for Molecular Sciences, University of Amsterdam, Nieuwe Achtergracht 166, 1018 WV Amsterdam, The Netherlands. g.vivotruyols@uva.nl
Abstract:
The watershed algorithm is the most common method used for peak detection and integration in two-dimensional chromatography. However, the retention time variability in the second dimension may render the algorithm to fail. A study calculating the probabilities of failure of the watershed algorithm was performed. The main objective was to calculate the maximum second-dimension retention time variability, Delta(2)t(R,crit), above which the algorithm fails. Several models to calculate Delta(2)t(R,crit) were developed and evaluated: (a) exact model; (b) simplified model and (c) simple-modified model. Model (c) gave the best performance and allowed to deduce an analytical expression for the probability of failure of the watershed algorithm as a function of experimental Delta(2)t(R), modulation time and peak width in the first and second dimensions. It could be demonstrated that the probability of failure of the watershed algorithm under normal conditions in GCxGC is around 15-20%. Small changes of Delta(2)t(R), modulation time and/or peak width in the first and second dimension could induce subtle changes in the probability of failure of the watershed algorithm. Theoretical equations were verified with experimental results from a diesel sample injected in GC x GC and were found to be in good agreement with the experiments.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry (UPLC-MS)
Published on: March 14, 2013
Related Concept Videos
Chromatographic Methods: Terminology
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process