Related Experiment Video
Updated: Jun 16, 2026

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
PAR immobilized colorimetric fiber for heavy metal ion detection and adsorption
Guowei Li1, Lianhai Zhang, Zhiwei Li
1Department of Chemistry, School of Sciences, Tianjin University, No 92 Weijin Road, Tianjin 300072, PR China.
Abstract:
A new wearable colorimetric fiber for heavy metal ion detection and adsorption has been synthesized by first aminating a commercially available polyacrylonitrile fiber with ethylenediamine and then covalently immobilizing 4-(2-pyridylazo)-1,3-benzenediol (PAR) on the modified fiber through a Mannich reaction. The fiber was characterized by X-ray powder diffraction spectra (XRD), scanning electron microscope (SEM), FTIR and UV-vis spectroscopy, and its acid exchange capacity, colorimetric properties, response speed, selectivity, reusability, photostability and adsorption capacity were investigated. In neutral aqueous solutions, the PAR immobilized fiber responds selectively to heavy metal ions, such as Hg(2+), Pb(2+), Cd(2+), Zn(2+), Ni(2+) and Cu(2+) with a color change from red-orange to dark-brown. Its visual detection limit for Pb(2+) is 1 x 10(-6)mol/L. Moreover, the selectivity increases with a decrease in pH, i.e. at pH 3.0, it shows a color change only for Hg(2+) and Cu(2+). This fiber also shows excellent reusability (>50 times), high photostability (>30 days under direct exposure to sunlight) and high adsorption capacity for Hg(2+) (0.74 mmol/g).
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
08:02Benchtop Immobilized Metal Affinity Chromatography, Reconstitution and Assay of a Polyhistidine Tagged Metalloenzyme for the Undergraduate Laboratory
Published on: August 23, 2018
Related Concept Videos
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Types of Detectors
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...