Related Experiment Video
Updated: Jun 16, 2026

Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
Short communication: repeatability of measures of rectal temperature in dairy cows
O Burfeind1, M A G von Keyserlingk, D M Weary
1Animal Welfare Program, Faculty of Land and Food Systems, The University of British Columbia, 2357 Main Mall, Vancouver, BC, V6T 1Z4, Canada.
Abstract:
Although taking body temperature by rectal thermometer is the method most commonly used to identify sick cows in the postpartum period, no data on the repeatability of this measure are available. The overall objective of this study was to evaluate variability of rectal temperatures in dairy cows considering different factors (intra- and interinvestigator repeatability, different thermometers, penetration depth into the rectum, and defecation). High coefficients of correlation (r=0.98) and small differences between values of rectal temperatures (observer A=39.3+/-1.0 degrees C and observer B=39.4+/-1.0 degrees C) provide evidence that rectal temperature was a repeatable measure in dairy cows. Testing was carried out using 4 different digital thermometers: GLA M750 (GLA Agricultural Electronics, San Luis Obispo, CA), MTI8101 (SES Scala Electronics, Stahnsdorf, Germany), MT1831 (Microlife AG, Widnau, Switzerland) and Domotherm TH1 (Uebe Medical GmbH, Wertheim, Germany). Thermometers were inserted into the rectum to a certain depth (GLA M750 and MTI8101=11.5cm; MT1831=8.4cm; Domotherm TH1=7.7cm) and a measure was finished when a visual or acoustic signal was emitted by the thermometer. The measures could be influenced by the procedure itself (up to 0.5 degrees C), type of thermometer (up to 0.3 degrees C), and the penetration depth (11.5cm or 6.0cm in one of the experiments) into the rectum (up to 0.4 degrees C difference between a penetration depth of 11.5cm and 6.0cm in one of the experiments). Differences in rectal temperature before and after defecation were minor (<0.1 degrees C). These results indicate that some care is required in generalizing rectal measures of body temperature.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...

