[Broken chest tube into the pleural cavity by a Monod' trocar]
A Gaucher1, Q Levrat, A Troitzky
1Service d'anesthésie réanimation, CHU de Poitiers, Poitiers, France.
Abstract:
We report the case of a 56-year-old man who presented a section of a chest drain into the pleural cavity. Following an oesogastrectomy with coloplasty for oesophageal carcinoma, the patient developed a pleural effusion. During the implementation of pleural drainage, the intrathoracic drain tip was sectioned. The patient underwent a thoracotomy to remove the foreign body. The drain was probably cut during device removal through the particularly cutting trocar. This observation strengthens the need to refrain from withdrawing the movement tube through a Monod trocar.
Related Concept Videos
Pneumothorax-II
Clinical Manifestations:
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pleura of the Lungs
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...