Simple apparatus for pulsed electric dichroism measurements
Applied Optics
|January 30, 2010
Summary
A new method simplifies measuring macromolecular solution alignment using electric fields. This longitudinal approach offers advantages over older transverse methods for dichroism analysis.
Area of Science:
- Biophysics
- Physical Chemistry
- Analytical Chemistry
Background:
- Electrically induced dichroism (EID) is a technique to study macromolecular alignment.
- Conventional EID methods use electric fields transverse to the optical beam, requiring variable polarization.
- These transverse methods can be complex and may necessitate multiple measurements.
Purpose of the Study:
- To introduce a novel, simplified method for measuring electrically induced dichroism.
- To present a longitudinal electric field arrangement for EID measurements.
- To theoretically derive the principles of the longitudinal EID method and compare it with transverse techniques.
Main Methods:
- A novel method employing pulsed electric fields applied longitudinally along the incident light path.
- Recording transient changes in solution absorption due to molecule alignment.
- Theoretical derivation of the EID effect for the longitudinal configuration.
- Experimental verification using an aqueous solution of the amylose triiodide complex.
Main Results:
- The longitudinal EID method eliminates the need for a polarizer.
- This arrangement is simpler and allows for data acquisition in a single measurement.
- The interrelation between longitudinal and conventional transverse EID measurements was confirmed.
- The method proved effective for analyzing the amylose triiodide complex.
Conclusions:
- The novel longitudinal EID method is a simpler and more efficient alternative to transverse techniques.
- This method provides valuable information on macromolecular alignment without complex optical setups.
- The findings validate the theoretical framework and practical applicability of the longitudinal EID approach for biophysical and chemical analyses.
Related Concept Videos
UV–Vis Spectrometers
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.