Related Experiment Video
Updated: Jun 16, 2026

Assessing Urinary Tract Junction Obstruction Defects by Methylene Blue Dye Injection
Published on: October 12, 2017
Real-time, near-infrared, fluorescence-guided identification of the ureters using methylene blue
Aya Matsui1, Eiichi Tanaka, Hak Soo Choi
1Division of Hematology/Oncology, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA 02215, USA.
Background:
The aim of this study was to determine whether the invisible near-infrared (NIR) fluorescence properties of methylene blue (MB), a dye already approved by the U.S. Food and Drug Administration for other indications, could be exploited for real-time, intra-operative identification of the ureters.
Methods:
The optical properties of MB were quantified in vitro. Open surgery and laparoscopic NIR fluorescence imaging systems were employed. Yorkshire pigs were injected intravenously with 0.1-mg/kg MB (n = 8), 10-mg furosemide followed by 0.1-mg/kg MB (n = 6), or 0.5-mg/kg MB (n = 6). The contrast-to-background ratio (CBR) of the kidney and ureters, and the MB concentration in the urine, were quantified.
Results:
Peak MB absorbance, emission, and intensity in urine occurred at 668 nm, 688 nm, and 20 mumol/L, respectively. After intravenous injection, doses as low as 0.1-mg/kg MB provided prolonged imaging of the ureters, and a dose of 0.5 mg/kg provided statistically significant improvement of CBR. The preinjection of furosemide increased urine volume but did not improve CBR. Laparoscopic identification of the ureter using MB NIR fluorescence was demonstrated.
Conclusion:
Ureteral imaging using MB NIR fluorescence provides sensitive, real-time, intra-operative identification of the ureters during open and laparoscopic surgeries.