Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview01:02

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview

Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material,  molecules absorb light depending on the energy required for electronic transitions. As a result...
Spectrophotometry: Introduction01:16

Spectrophotometry: Introduction

Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
IR Spectroscopy: Molecular Vibration Overview01:24

IR Spectroscopy: Molecular Vibration Overview

When Infrared (IR) radiation passes through a covalently bonded molecule, the bonds transition from lower to higher vibrational levels. The fundamental vibrational motions that result in infrared absorption can be classified as stretching or bending vibrations.
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A UHV-compatible, time-resolved spontaneous Raman spectrometer for multi-messenger ultrafast studies: Design and applications to photoinduced dynamics.

Structural dynamics (Melville, N.Y.)·2025
Same author

Risk factors and outcomes of restorative proctocolectomy with ileal pouch-anal anastomosis for ulcerative colitis. Retrospective study of 75 single center cases.

European review for medical and pharmacological sciences·2023
Same author

The impact of COVID-19 pandemic on IBD surgery: a single center experience.

European review for medical and pharmacological sciences·2022
Same author

Hydrogen-bond network distortion of water in the soft confinement of Nafion membrane.

The Journal of chemical physics·2021
Same author

New perspectives in the prediction of postoperative complications for high-risk ulcerative colitis patients: machine learning preliminary approach.

European review for medical and pharmacological sciences·2020
Same author

Total hip replacement: a retrospective multicentric analysis on re-intervention rate after single component revision.

Journal of biological regulators and homeostatic agents·2020
Same journal

Multifunctional reconfigurable terahertz metasurface based on vanadium dioxide phase transition: achieving broadband absorption and efficient polarization conversion.

Applied optics·2026
Same journal

High-Q-factor electromagnetically induced transparency utilizing quasi-bound states in the continuum in an all-dielectric terahertz metasurface.

Applied optics·2026
Same journal

Automated stitching interferometry for high-precision metrology of X-ray mirrors.

Applied optics·2026
Same journal

Experimental demonstration of an approach to designing a metal-dielectric DBR resonant cavity structure.

Applied optics·2026
Same journal

High-precision wavefront reconstruction from a single-shot interferogram using a physics-driven hybrid feature calibration network.

Applied optics·2026
Same journal

Ultra-high-Q Fano resonance based on coupled topological corner states in Kagome photonic crystals.

Applied optics·2026
See all related articles

Related Experiment Video

Updated: Jun 16, 2026

Method for Recording Broadband High Resolution Emission Spectra of Laboratory Lightning Arcs
07:51

Method for Recording Broadband High Resolution Emission Spectra of Laboratory Lightning Arcs

Published on: August 27, 2019

Spectroscopy by grating synthesis.

G A De Biase, F Sacchetti, D Trevese

    Applied Optics
    |February 2, 2010
    PubMed
    Summary
    This summary is machine-generated.

    Synthesizing multiple diffraction gratings can enhance spectral information capture. This method, even with imperfections, offers comparable data to a single equivalent grating, advancing spectroscope design.

    More Related Videos

    Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy
    08:49

    Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy

    Published on: December 1, 2023

    Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
    09:46

    Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging

    Published on: April 28, 2022

    Related Experiment Videos

    Last Updated: Jun 16, 2026

    Method for Recording Broadband High Resolution Emission Spectra of Laboratory Lightning Arcs
    07:51

    Method for Recording Broadband High Resolution Emission Spectra of Laboratory Lightning Arcs

    Published on: August 27, 2019

    Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy
    08:49

    Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy

    Published on: December 1, 2023

    Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
    09:46

    Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging

    Published on: April 28, 2022

    Area of Science:

    • Optics and Spectroscopy
    • Diffraction Grating Technology

    Background:

    • Traditional spectroscopy relies on single diffraction gratings.
    • Limitations exist in information capacity and aberration control with single gratings.

    Purpose of the Study:

    • To investigate spectral information enhancement through diffraction grating synthesis.
    • To explore the feasibility of a synthesis spectroscope accounting for imperfections.
    • To compare the information yield of synthesized gratings versus single gratings.

    Main Methods:

    • Theoretical study of spectral information from synthesized diffraction gratings.
    • Analysis of systems with two gratings (fixed and in relative motion) and N fixed gratings.
    • Consideration of grating aberrations and construction imperfections in a synthesis spectroscope model.

    Main Results:

    • Grating synthesis enables transfer functions that increase obtainable spectral information compared to a single grating.
    • A synthesis spectroscope design is proposed, addressing aberrations and imperfections.
    • Numerical elaboration confirms that the synthesis method yields information comparable to a single equivalent grating.

    Conclusions:

    • Diffraction grating synthesis is a viable method for enhancing spectral information.
    • The proposed synthesis spectroscope offers potential advantages in information capacity.
    • This technique provides a robust alternative to conventional single-grating spectroscopes.